Fall Sensor-3                                       

This fall sensor is designed to activate the Control Panel by manual button press or auto fall detection to summon help in 
emergency condition.   

A. Identifying the Parts 

1. Lanyard Loop 

2. Green/Red LED 

 

Green LED FLASH for 1 second: When powered on. 

 

Green LED FLASH: Transmitting signal to the Control Panel. 

 

Red LED FLASH: Transmitting signal to the Control Panel under low battery 
condition. 

 

Red LED FLASH for 3 times: Low battery status detected when powered on.   

3. Active Button   

 

Press and hold the Active Button for more than 2 seconds to activate 

the Control Panel.

 

 

 

Press and hold the button for 5 seconds to cancel the alarm. 

 

Press and hold the button for 8 seconds to receive sensitivity level 
data from the Control Panel. 

4. Battery Compartment Cover 

B. Low Battery Detection and Supervision   

Fall Sensor features Auto Low Battery detection and Supervision. 

 

 

The Fall Sensor will automatically transmit a Low Battery detection & Supervisory code to the Control Panel every 
30~50 minutes.   

C. Learn In Fall Sensor   

Step 1. Put the Control Panel into Learning Mode (Please refer to the Control Panel manual for details.) 

Step 2. Press and hold the Active Button of Fall Sensor for more than 2 seconds. A radio signal will be transmitted to the 

Control Panel. 

Step 3. Please refer to the operation manual of your Control Panel to complete the learning process. 

D. Battery   

The Fall Sensor uses one CR2477 3V lithium battery as its power source.   

If the battery voltage is low, a Low Battery signal will be sent to the Control Panel to notify the user. Moreover, when 
activated under low battery status, the Red LED will flash to remind the user to replace the battery. 

<NOTE> 

 

It is prohibited to learn in Fall Sensor to the Control Panel when It is in low battery status. 

E. Sensitivity Level Adjustment 

The  Fall Sensor sensitivity  is  programmable from the Control Panel. Five sensitivity levels are available for selection. 
Level 1 refers to lowest sensitivity level, while Level 5 refers to highest sensitivity level.   

  Sensitivity Level 

Values 

Level 1 

130ms 

Level 2 

110ms 

Level 3 

90ms (default) 

Level 4 

70ms 

Level 5 

50ms 

 

 