Climax Technology EMD-1ZBS Manual Download Page 3

 

3

Wall Mounting 

The Energy Meter has two mounting holes on the back for wall mounting. 
1. Mark the mounting location on the wall according to mounting hole position 
2. Install two screws at the mounting location. 
3. Hook the Energy Meter onto the screws. 
 

 

Energy Consumption Monitor 

  The Energy Meter reads LED pulse from the watt hour meter to monitor energy consumption. 

  The Energy Meter will transmit current wattage every 5 minutes to ZigBee network coordinator 

  The Energy Meter transmits a power data to coordinator whenever accumulated power usage increases 

by 0.1kW/hr. 

  To clear the Energy Meter of its accumulated power consumption data, follow steps below: 

1. 

Remove the batteries to power down. 

2. 

Press and hold the function button and reinsert batteries again when holding down the button. 

3. 

Keep holding the button and release after 3 seconds. The accumulated power consumption data 
will be cleared. 

 

Appendix 

(For developers only)

 

 

Power Switch Cluster ID 

Device ID: Meter Interface :

 

0x0053 

Endpoint:0x01

 

Server Side 

Client  Side 

Mandatory 

Basic (0x0000) 

Identify(0x0003)

 

Metering(0x0702) 

 

Meter Identification(0x0B01) 

 

Optional 

Power Configuration(0x0001)

 

None 

Identify(0x0003) 

 

 

Attribute of Basic Cluster Information 

Identifier 

Name 

Type 

Range 

Access 

Default 

Mandatory 

/ Optional

0x0000 

ZCLVersion 

Unsigned 

8-bit integer

0x00 –0xff

Read only

0x01 

0x0001 

ApplicationVersion 

Unsigned 

8-bit integer

0x00 –0xff

Read only

0x00 

0x0003 

HWVersion 

Unsigned 

8-bit integer

0x00 –0xff

Read only

0x0004 

ManufacturerName 

Character 

String 

0 – 32 

bytes 

Read only

Climax 

Technology 

0x0005 

ModelIdentifier 

Character 

String 

0 – 32 

bytes 

Read only

(Model Version) 

0x0006 

DateCode 

Character 

String 

0 – 16 

bytes 

Read only

 

0x0007 

PowerSource 

8-bit 

0x00 –0xff

Read only

 

0x0010 

LocationDescription 

Character 

String 

0 – 32 

bytes 

Read / 

Write 

 

0x0011 

PhysicalEnvironment 

8-bit 

0x00 –0xff

Read / 

Write 

0x00 

0x0012 

DeviceEnabled 

Boolean 

0x00 –0x01

Read / 

Write 

0x01 

 

Attribute of Power Configuration Cluster Information 

Identifier 

Name 

Type 

Range 

Access

Default 

Mandatory 

/ Optional

0x0035 

BatteryAlarmMask 

8-bit 

bitmap 

0000 000x 

Read / 

Write 

0000 0000 

 