Wall Mounting
The Energy Meter has two mounting holes on the back for wall mounting.
1. Mark the mounting location on the wall according to mounting hole position
2. Install two screws at the mounting location.
3. Hook the Energy Meter onto the screws.
Energy Consumption Monitor
The Energy Meter reads LED pulse from the watt hour meter to monitor energy consumption.
The Energy Meter will transmit current wattage every 5 minutes to ZigBee network coordinator
The Energy Meter transmits a power data to coordinator whenever accumulated power usage increases
by 0.1kW/hr.
To clear the Energy Meter of its accumulated power consumption data, follow steps below:
1.
Remove the batteries to power down.
2.
Press and hold the function button and reinsert batteries again when holding down the button.
3.
Keep holding the button and release after 3 seconds. The accumulated power consumption data
will be cleared.
Appendix
(For developers only)
Power Switch Cluster ID
Device ID: Meter Interface :
0x0053
Endpoint:0x01
Server Side
Client Side
Mandatory
Basic (0x0000)
Identify(0x0003)
Metering(0x0702)
Meter Identification(0x0B01)
Optional
Power Configuration(0x0001)
None
Identify(0x0003)
Attribute of Basic Cluster Information
Identifier
Name
Type
Range
Access
Default
Mandatory
/ Optional
0x0000
ZCLVersion
Unsigned
8-bit integer
0x00 –0xff
Read only
0x01
M
0x0001
ApplicationVersion
Unsigned
8-bit integer
0x00 –0xff
Read only
0x00
O
0x0003
HWVersion
Unsigned
8-bit integer
0x00 –0xff
Read only
0
O
0x0004
ManufacturerName
Character
String
0 – 32
bytes
Read only
Climax
Technology
O
0x0005
ModelIdentifier
Character
String
0 – 32
bytes
Read only
(Model Version)
O
0x0006
DateCode
Character
String
0 – 16
bytes
Read only
O
0x0007
PowerSource
8-bit
0x00 –0xff
Read only
M
0x0010
LocationDescription
Character
String
0 – 32
bytes
Read /
Write
O
0x0011
PhysicalEnvironment
8-bit
0x00 –0xff
Read /
Write
0x00
O
0x0012
DeviceEnabled
Boolean
0x00 –0x01
Read /
Write
0x01
M
Attribute of Power Configuration Cluster Information
Identifier
Name
Type
Range
Access
Default
Mandatory
/ Optional
0x0035
BatteryAlarmMask
8-bit
bitmap
0000 000x
Read /
Write
0000 0000
O