![Climax Technology ACGS-23ZW Manual Download Page 4](http://html1.mh-extra.com/html/climax-technology/acgs-23zw/acgs-23zw_manual_2625023004.webp)
4
Z-Wave Information
Generic Type:
Sensor Notification
Specific Type:
Notification Sensor
Product Type ID:
0x0003
Product ID:
0x0000E
Device Type:
Sensor- Notification
Role Type:
Reporting Sleeping Slave (RSS)
Command Class Support/Control
Mandatory CC Support:
Z-Wave Plus Info CC, V2
Association CC, V2
(security 2)
Multi Channel Association CC, V3
(security 2)
Association Group Information CC
(security 2)
Transport Service CC, V2
Version CC, V3
(security 2)
Manufacturer Specific CC, V2
(security 2)
Device Reset Locally CC
(security 2)
Powerlevel CC
(security 2)
Battery CC
(security 2)
Security 2 CC
Notification CC, V8
(security 2)
Wake UP CC, V2
(security 2)
Supervision CC
Firmware Update MD CC, V4
(security 2)
Z-Wave’s Groups (Association Command Class Version 2)
Group 1 for “LifeLine” (max node = 1):
Notification CC,V3 (COMMAND_CLASS_NOTIFICATION)
Battery CC (COMMAND_CLASS_BATTERY)
Device Reset Locally CC
Notification Report
1. If Glass Break Detector is triggered, it will send a Notification Report (Type: 0x07, Event 0x06).
2. If tamper is open, it will send Notification Report (Type: 0x07, Event: 0x03)
3. If tamper is closed, it will send Notification Report (Type: 0x07, Event: 0x00, Parmeter:0x03).
Battery Report
1. If battery level changes, it will send Battery Report (0x64, 0x4B, 0x32, 0x19, or 0xFF)
respectively.