Climax Technology ACGS-23ZW Manual Download Page 4

 

Z-Wave Information 

Generic Type:

 Sensor Notification 

Specific Type:

 Notification Sensor 

Product Type ID: 

0x0003 

Product ID: 

0x0000E 

Device Type:

 Sensor- Notification 

Role Type:

 Reporting Sleeping Slave (RSS) 

Command Class Support/Control 

Mandatory CC Support:   

Z-Wave Plus Info CC, V2 

 

 

 

 

 

 

Association CC, V2 

(security 2) 

 

 

 

 

 

 

Multi Channel Association CC, V3 

(security 2) 

 

 

 

 

 

 

Association Group Information CC 

(security 2) 

 

 

 

 

 

 

Transport Service CC, V2 

 

 

 

 

 

 

Version CC, V3 

(security 2) 

 

 

 

 

 

 

Manufacturer Specific CC, V2 

(security 2) 

 

 

 

 

 

 

Device Reset Locally CC 

(security 2) 

 

 

 

 

 

 

Powerlevel CC 

(security 2) 

 

 

 

 

 

 

Battery CC 

(security 2) 

 

 

 

 

 

 

Security 2 CC 

 

 

 

 

 

 

Notification CC, V8 

(security 2)

 

                                                     Wake UP CC, V2   

(security 2) 

  

 

 

 

 

 

Supervision CC 

  

 

 

 

 

 

Firmware Update MD CC, V4 

(security 2)

 

 

Z-Wave’s Groups (Association Command Class Version 2)

 

Group 1 for “LifeLine” (max node = 1): 

  

Notification CC,V3 (COMMAND_CLASS_NOTIFICATION)

 

          Battery CC (COMMAND_CLASS_BATTERY)

 

          Device Reset Locally CC

 

Notification Report

 

1.  If Glass Break Detector is triggered, it will send a Notification Report (Type: 0x07, Event 0x06). 

2.  If tamper is open, it will send Notification Report (Type: 0x07, Event: 0x03) 

3.  If tamper is closed, it will send Notification Report (Type: 0x07, Event: 0x00, Parmeter:0x03). 

Battery Report

 

1.  If battery level changes, it will send Battery Report (0x64, 0x4B, 0x32, 0x19, or 0xFF) 

respectively. 
 

Reviews: