MAINTENANCE
The ClimateRight® climate control unit is a low maintenance product and
does not require much attention if used in normal environments. However, two
components will require periodic cleaning to ensure maximum heating and
Failure to property care for the ClimateRight® unit as mentioned above will
result in a voided Warranty.
FILTERS
CONDENSER
The condenser is located on the side of the unit with the open grid. If the cooling
. Debris on
Use a garden hose with a spray nozzle set on a gentle setting to rinse away dirt and
debris.
EVAPORATOR
If the unit is installed in a location with lots of dirt, debris and pet fur
not screen all contaminants from the air. If the evaporator becomes heavily soiled
with debris, it may be necessary to clean the evaporator.
To clean the evaporator, carefully remove the sheet metal surrounding the top and
sides of the unit. Use a soft bristle brush, such as a paintbrush to gently brush away
TROUBLSHOOTING
PROBLEM
POSSIBLE CAUSES
WHAT TO DO
Air conditioner does
not start.
The air conditioner
is unplugged.
Check that the air
conditioner plug is
inserted completely into
the outlet.
The fuse is blown or
the circuit breaker
has been tripped.
Check the house fuse/
circuit breaker box and
replace the fuse or reset
the breaker.
Power failure.
The unit will automatically
re-start in the settings last
used after the power is
restored.
There is a protective time
delay (approximately 3
minutes) to prevent
tripping of the
compressor overload. For
this reason, the unit may
not start normal cooling
for 3 minutes after it is
turned back on.
Water builds up in
unit.
Clogged drain hole
Check the drain hole and
unclog if it is blocked.
Make sure the unit is on a
level surface.
NORMAL OPERATING SOUNDS
• The thermostat may click when the comp
ressor cycles on and off.
• Fan
• Cont
rol Beep