background image

6

Do Not Operate in Freezing Outdoor Conditions 

This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used in freezing outdoor 

conditions.

Remote Control

How to Insert the Batteries in the Remote Control

1.  Remove the battery cover by sliding it according to the arrow direction.

2.  Insert new batteries, making sure that the (+) and (–) of battery are installed correctly.

3.  Reattach the cover by sliding it back into position.

NOTES:

■ Use 2 “AAA” (1.5 volt) alkaline batteries. Do not use rechargeable batteries.

■ Remove the batteries from the remote control if the system is not going to be used for a long time.

■ To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.

■ The remote control signal has a range of up to 20 feet. 

■ Make sure nothing is between the air conditioner and the remote that could block the signal.

■ Make sure batteries are fresh and installed correctly as indicated on the remote control.

Cool Mode

Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase ▲/ Decrease 

▼pads to set the desired temperature between 64°F and 86°F in 1°F increments.  An electronic thermostat is used to 

maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort.  Set the 

thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor 

air will become warmer.

Cooling Descriptions

For Normal Cooling

—Select the Cool mode and High or Med fan with a middle set temperature.

For Maximum Cooling

—Select the Cool mode and High fan with a lower set temperature.  

For Quieter & Nighttime Cooling

—Select the Cool mode and Low fan with a middle set temperature.

NOTE:

 If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool 

setting, it may take approximately 3 minutes for the compressor to start and cooling to begin. 

Energy Saver Mode

Controls the fan. 

ON

—The fan will cycle on and off with the compressor. This results in wider variations of room temperature and humidity. 

Normally used when the room is unoccupied.

 

OFF

—The fan runs all the time, while the compressor cycles on and off.

NOTE:

 The fan may continue to run for a short time after the compressor cycles off.

Fan Only Mode

Use the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan 

only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the 

display. 

NOTE:

Auto Fan Speed cannot be used when in the Fan Only Mode.

Auto Fan Speed 

Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings 

with the set temperature.  If the room needs more cooling, the fan speed will automatically increase. If the room needs 

less

cooling, the fan speed will automatically decrease.

NOTE:

 Auto Fan Speed cannot be used when in the Fan Only Mode.

Power Outage Recovery Feature

In the case of a power outage or interruption, the unit will automatically re-start in the settings last used after the power is 

restored. If the Delay 1–24hr feature was set, it will resume countdown. You may need to set a new time if desired.

OPERATING INSTRUCTIONS

Summary of Contents for CR-5000-AC

Page 1: ...Climate Comfort Anyplace Imaginable OWNER S MANUAL FPO Safety Instructions Overview and Specifications Operating Instructions Troubleshooting Warranty Registration 2 3 4 5 7 8 9 10...

Page 2: ...y circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded DO NOT use an adapter plug with this appliance The power cord of t...

Page 3: ...hat it be a UL listed 14 gauge 3 wire grounding type appliance extension cord having a grounding type plug and outlet and that the electrical rating of the cord be 15 amperes minimum and 125 volts REA...

Page 4: ...Room enclosure size Up to 800 cu ft Volts 115 Amps 4 9 Operating Watts 520 W Dehumidifying pts hr 1 1 Thermostat Digital w infrared remote control Control Panel features Auto off timer 3 fan and cool...

Page 5: ...ol use the fan speed In crease Decrease pads to set the fan speeds to Low Med or High Use the Auto pad to turn Auto fan on Mode Pad Use to set the air conditioner to Cool Energy Saver or Fan Only mode...

Page 6: ...middle set temperature For Maximum Cooling Select the Cool mode and High fan with a lower set temperature For Quieter Nighttime Cooling Select the Cool mode and Low fan with a middle set temperature...

Page 7: ...k often as required Condenser On the back of the unit there is the condenser If you notice the cooling ability of the unit degrading or if the fins of the condenser become dirty they will need to be c...

Page 8: ...The room my have been hot Make sure there are no curtains blinds or furniture blocking the supply or return air vents In the Cool mode press the Decrease pad Clean the filter at least every 30 days Wh...

Page 9: ...ms any of the following apply the warranty is void regardless of purchase date Units Labor charges after one 1 year of date of purchase Labor charges for installation setup or training to use the prod...

Page 10: ...hase date clearly visible Unless otherwise noted through registration the warranty will start the shipment delivery date We will not sell or rent your information to any third party The data collected...

Reviews: