![ClimateMaster AVB32V03C Owner'S Manual & Installation Instructions Download Page 85](http://html1.mh-extra.com/html/climatemaster/avb32v03c/avb32v03c_owners-manual-and-installation-instructions_2624778085.webp)
77
1 Stage Heat, 1 Stage Cool
(with wired remote sensor)
D/H
W
O
SENSOR
W1
Y1
G
R
C
Dip Switch
Settings
10K NTC
Thermistor
ACC-TSEN
or ACC-DSEN
1
GAS
O
GAS/EL
ELEC
B
HP
ON
23
Notes:
1) Connect the two wires from the sensor to the two SENSOR terminals. To
enable the function, set MENU > Settings > Installation Settings > AUX IN use
to “Use as remote sensor” if you wish to control to the temperature from the
sensor or “Use as supply sensor” or “Use as return sensor” to simply monitor
the temperature