background image

 
 
 

2.1 Display 

 

The display also shows status and eventual alarms through the 8 specific symbols: 

 
 

 

 

2.2 Keyboard 

 

The various functions are set with the 8 backlit keys  

 

 

 

2.3 General switch on 

 

-  To manage the device through the control panel, it must be connected to the mains. 
-  In case of a general switch on the mains supply line, it must be switched on. 
-  Switch on the system with the main switch. 

 

2.4 Activation 

 

To activate the device 

 

 

 
 
 
 

A

Active cooling

Silent function selected

Maximum ventilation  speed selected

Night function selected

Active heating

Alarm signal

OFF

Heating element (blinking light)

heating element activated (fixed light)

Automatic function selected 

+

-

Auto

Makes    ventilation    speed   adjustment completely  automatic  
between  a  minimum and maximum value.

Silent : allows to limit the ventilation  speed to a more  contained maximum 
value

Temp  + allows to increase set temperature

Night function : ventilation  speed is limited to a very contained value, and the 
set temperature is automatically changed.

Temp  - allows to decrease set temperature

Max:  allows  to  set  the  maximum  ventilation speed.

Heating  / Cooling : allows  to switch operation mode  between 
heating  and cooling.

ON/Stand-By: Allows to activate  the device  or to put it in standby.

KEY

DISPLAY

The display lights up

Auto

Auto

Press ON standby.

OPERATION

Select  one of the 4 operation modes by pressing the relative key

Summary of Contents for SILICIUM HYBRID

Page 1: ...USER S GUIDE SILICIUM HYBRID INVERTER...

Page 2: ......

Page 3: ...Low tension directive 2006 95 CE Electro magnetic compatibility 2004 108 CE 2002 95 EC Restriction of Hazardous Substances in electrical and electronic equipment RoHS 2002 96 EC Waste Electrical and E...

Page 4: ...g light heating element activated fixed light Automatic function selected Auto Makes ventilation speed adjustment completely automatic between a minimum and maximum value Silent allows to limit the ve...

Page 5: ...KEY OPERATION DISPLAY Set the desired temperature value shown on the 3 digits of the display with the aid of the two increase and decrease keys The adjustment range goes from 16 to 28 C with 0 5 C res...

Page 6: ...ited to a very contained value and the set temperature is automatically changed as follows decreased by 1 C after one hour and an additional degree after 2 hours in heating function increased by 1 C a...

Page 7: ...the painted surfaces When necessary clean the outer surfaces of the Air Leaf cooler convector with a soft cloth damp cloth 3 2 Cleaning air suction filter After a period of continuous operation and in...

Page 8: ...mit where possible the effect of direct sun rays in the rooms being conditioned use curtains shutters etc 4 Troubleshooting 4 1 Troubleshooting In case of water leaks or anomalous functioning immediat...

Page 9: ...The appliance leaks water during the heating function Leaks in the hydraulic connections of the system Check the leak and fully tighten the connections Leaks in the valve unit Check the state of the...

Page 10: ...and poor electricity supply to the system This warranty is also excluded if it is used with another purpose other than heating for an alteration modification tampering or unauthorized repairing of the...

Page 11: ......

Page 12: ...CLIMASTAR GLOBAL COMPANY S L Carretera AS 266 OVIEDO PORCEYO Km 7 Pruvia 33192 Llanera Asturias SPAIN Tel 34 985 66 80 80 Fax 34 985 264 751 www climastar es HYBRID INVERTER User Rev 270120...

Reviews: