Summary of Contents for RevoFit2

Page 1: ...niquement par un professionnel certifié formé au système RevoFit Le filament sera porté inspecté et remplacé régulièrement Beratend Nicht bei Patienten mit Neuropathie Neuromen oder anderen Nervenproblemen anwenden Fertigung nur durch einen zertifizierten Fachmann der im RevoFit System geschult wurde Filament wird regelmäßig getragen kontrolliert und ersetzt Consultivo No lo use en pacientes con n...

Page 2: ......

Page 3: ...or Above Knee 2 System with Medial Lateral Panels Adjustable Strap Recommended Suspension System RevoLock Lanyard Kit PN 3000 220 05 Patient Replacement Lace Pack Additional Kit Required Accedents happen WE GET IT For any warranty or product failure please do not return to distributor simply contact CLICK MEDICAL DIRECTLY AT Help ClickMedical co Help Line 970 670 7012 WARRANTY ...

Page 4: ...nt Determine lace routing For Inline Routing Use port II and III For Remote Routing Use port I and II Inline mounted on panel Remote mounted on socket frame Inline mounted on socket frame Determine location of reel Glue on RevoFit Components Laminate Cut Out Windows 4 Install Shape Pads Lace Socket Install Reel Tune Pads ...

Page 5: ...ith the spacing rule b Ensure tubing crosses panels perpendicularly c Don t turn tubing until 1cm past any panel edge Do not kink tubing 1 2 1 4 1 4 1 4 1 4 Laminate again 7 Glue on tubing 5 Trim one tube pack with clay insert into bayonet c Insert Tube Make sure tubing is inserted 2cm into silicone 6 b Pack Clay Cut off tabs for lamination a Cut at an angle so tube pierces into the silicone easil...

Page 6: ...on at an angle creating a tunnel to access the pilot hole release tab 2mm drill bit Test and clear hole before installing dial Fabricate and install pads 12 Pad thickness material and shape are used to refine pressure and fit Pad Material Pads should be dense enough to create pressure and not compress under tension Pad Thickness Average 3 16 4 75mm Push shore 35 Slight convex shape allows for bett...

Page 7: ...eedle nose vise grips Rotate clockwise to remove Tab location Finished Push towards center of reel 1 4 turn Turn the housing not the dial itself Pull dial to open Inline Depending on the location either at 4 o clock or 11o clock Always at 8 30 Remote Fit patient Tune in fit by refining pad shape if necessary Provide IFU s and replacement lace pack to patient a Open dial b Use tool to press inward ...

Page 8: ... PEL LLC ph 800 321 1264 www pelservice com Distributed by ...