![Cli-mate CLI-DH12 Installation & Operating Instructions Manual Download Page 10](http://html.mh-extra.com/html/cli-mate/cli-dh12/cli-dh12_installation-and-operating-instructions-manual_2624014010.webp)
8
INSTALLATION AND OPERATING INSTRUCTIONS
E. OPTIONAL CONTINUOUS DRAINAGE INSTALLATION
1. Ensure that unit is OFF and unplugged from wall socket.
2. Remove water reservoir out and connect water drain hose to
spigot (continuous drainage outlet) as shown in figure 2.
3. The other end of this hose must be placed over a water drain.
Note:
For the unit to drain correctly, no part of the hose should be
above the level of the water spigot (continuous drainage outlet).
F. MAINTENANCE AND REPAIR
Before carrying out any maintenance or cleaning of the unit, make
sure that the power to the unit is turned off and power cord is
removed from the power socket.
External cleaning of unit:
• Do not clean unit with any abrasive cleaning agents or solvents.
• Do not apply any water directly to the unit of cleaning.
• Only use a soft clean cloth for all cleaning purpose
Cleaning Filter:
Remove Air Intake Frame as shown in figure 3 below to access air
filter. Use a vacuum cleaner or wash in cool water to clean filter.
Allow to dry thoroughly before replacing filter and Air Intake Frame.
Fig 2
Water spigot
Fig 3
Air Intake Frame
Air Filter