CLEANING THE HEPA AND ACTIVATED CARBON FILTER
It is recommended that the HEPA and activated carbon filters are
cleaned every 100-500 hours of unit operation, depending on the
air quality of the room.
To clean the HEPA and Activated Carbon Filter:
1. Turn off unit and disconnect the power.
2. Place both hands at the bottom corners of the rear cover, and
pull out.
3. Pull out the 4 filters by the white belt attached
4. Gently peel away the Pre-filter layers
5. Run a vacuum cleaner with a nozzle or brush attachment on
low power setting along the HEPA (white side) and Activated
Carbon (black side) filters to pick up the dust and various
particles.
6. Re-attach Pre-filter layers and place back into the air purifier.
Note: When placing the filters back into the air purifier, ensure
that the white belts are facing outwards and that the Pre-Filters
are facing towards the air inlet
REPLACING FILTER
When the lifespan of the 3-layer filter reaches it end, the POWER
light will flash blue, indicating that it needs to be changed.
Discard the old filter and replace with a new one. It is not reusable.
The lifespan and duration of the filter depends on the air quality
and surrounding environment. The higher level of pollutants, the
shorter the filter lifespan. It is advisable to change the filter at
least every 8 months or 1500 hours of unit operation.
Cli~Mate Replacement Filter Product Code: CLI-RF-AP30.
HOW TO REPLACE THE FILTER
1. Turn off unit and disconnect the power.
2. OPEN THE REAR COVER: Place both hands at the bottom
corners of the rear cover, and pull out.
3. REMOVE THE FILTER: Pull out the filters by the white belt
attached and discard.
4. INSTALL NEW FILTER: Replace with new filters. Ensure that
that the white belt is facing outwards and that the Pre-Filter is
facing towards the air inlet.
5. Reattach the rear cover.
6. Hold down Speed