9
Care & Cleaning
• Do not rinse the unit or immerse the unit
in water.
• Do not use detergent to clean any water-
containing parts of the humidifier.
• Do not use abrasive cleaners or brushes
to clean.
• Clean the surface of the device with
a soft cloth.
SCALE
To reduce the possibility of scale (white mineral
deposits) build-up on the surface of the water
basins, inner surface of the water tank and
transducer, the following is recommended:
• Change the water daily.
• If possible, use distilled or demineralised
water.
• Drain, clean and thoroughly dry all parts
of the unit before putting it into storage.
STORAGE
If you do not plan to use the unit for an
extended period of time empty water tank and
base completely. Do not store with water inside
base or water tank. Allow all components to
dry completely before storing. Store in a cool
dry location.
CAUTION:
Before carrying out cleaning or maintenance of the product, always turn off and unplug
the cord from the power socket.
CLEANING THE TRANSDUCER
If mineral deposits are evident on or around
the transducer clean the surface with a soft,
clean cloth and a small amount of undiluted
white vinegar. To remove mineral deposits, put
5-10 drops of undiluted white vinegar on the
surface of the transducer. Leave to soak for 2-5
minutes. Use a cotton swab to gently loosen up
the scale of the surface. Rinse the transducer
with clean water and wipe clean.
IMPORTANT
Be careful not to damage the Transducer
during cleaning. Do not use any metal to
scrape it or touch with bare fingers.
Transducer