CLF BEAM 6 Manual Download Page 1

manual

V1.0 NOVEMBER 2017

WWW.CLF-LIGHTING.COM

beam 6

Summary of Contents for BEAM 6

Page 1: ...manual V1 0 NOVEMBER 2017 WWW CLF LIGHTING COM beam 6 ...

Page 2: ... Dimensions 4 Photometric data 5 Physical installation 5 Mounting 6 Power and signal connection 7 Power connection 8 Control mode 9 Circuit connecting diagrtam 9 Onboard control menu 10 DMX protocol 14 Cleaning and maintenance 16 Specifications 16 table of CONTENTS ...

Page 3: ...sk of severe injury or death DANGER Hazardous voltage Risk of lethal or severe electric shock WARNING Fire hazard WARNING LED light emission Risk of eye injury WARNING Burn hazard Hot surface Do not touch WARNING Wear protective eyewear WARNING Refer to user manual llowing symbols are used to identify important safety information on the product and in this manual WARNING Read the safety precaution...

Page 4: ...WWW CLF LIGHTING COM 4 fixture overview WWW CLF LIGHTING COM 6 0 operation panel dimensional drawings 155 268 226 dimensions WWW CLF LIGHTING COM 6 0 operation panel dimensional drawings 155 268 226 ...

Page 5: ...et physical installation CAUTION Before mounting the fixture to any surface make sure that the installation area can hold a minimum point load of 10 times the device s weight Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable To avoid injury never stand directly below the device when mounting removing or servicing the fixture MOUNTING...

Page 6: ...erational in any mounting position Be sure the fixture is kept at least 50cm away from any flammable materials decoration etc When mounted with a clamp always use and install the supplied safety cable as a safety measure to prevent accidents Quicklock ...

Page 7: ...core is at least a diameter of 0 5mm Notice The inside leading wire of the 5 pin XLR plug can t touch each other or the earth We recommend to use the DMX signal terminator during the installation to avoid electronic reflection of the digital control signal The DMX terminator is a XLR connector with a 120Ω 1 2W resistor connected across pin 2 and 3 see picture on the right Which is plugged into the...

Page 8: ...WWW CLF LIGHTING COM 8 power connection WWW CLF LIGHTING COM 10 0 light power connection working normally Do not daisychain more then 6 fixtures ...

Page 9: ...e 17 Slave ID 3 Shutter 8 Macro color 13 Rota lens 4 Red 9 Pan 14 Rota speed 5 Green 15 Fixture control circuit connection diagram STANDARD 11CH 1 Dimmer 4 Green 7 Pan 10 Rota speed 2 Shutter 5 Blue 8 Tilt 11 Fixture control 3 Red 6 White 9 Rota lens control mode STANDARD 17CH 1 Dimmer 6 Blue 11 Tilt 16 Calibration 2 Dimmer fine 7 White 12 Tilt fine 17 Slave ID 3 Shutter 8 Macro color 13 Rota lens...

Page 10: ...gram 4 Program 5 Program 6 Program 7 Program 8 Slave Master Slave mode Master mode Info Fixture times Power on time H Lamp on time H Fixture temperature Lamp_tem C RDM UID DMX live 1 Dimmer 0 255 2 Dimmer fine 3 Shutter 4 Red 5 Green 6 Blue 7 White 8 Macro color 9 Pan 10 Pan fine 11 Tilt 12 Tilt fine 13 Rota lens 14 Rota sp 15 Fixturecontrol 16 Calibration 17 Slave ID Version info LED_XY_SOFT V2 0...

Page 11: ...rt OFF Default ON DMX reset ON Default OFF Reset System reset Quick closedown ON Default OFF P T angle limit Close Open Program on off Close Open Set P T angle Pan start Pan end Tilt start Tilt end Display Display sleep Light always 2 minutes 4 minutes 6 minutes Display intensity 10 100 Display rotation Rotate 180 Normal TFT calibration ...

Page 12: ...an 10 Pan fine 11 Tile 12 Tilt fine 13 Rota lens 14 Rota sp 15 Fixturecontrol 16 Calibration 17 Slave ID MENU MENU IV Program Edit program Edit program 1 Scene 0 100 1 Dimmer 0 255 2 Dimmer fine 3 Shutter 4 Red 5 Green 6 Blue 7 White 8 Macro color 9 Pan 10 Pan fine 11 Tilt 12 Tilt fine 13 Rota lens 14 Rota sp 15 Fixturecontrol 16 Calibration 17 Slave ID Save scene ...

Page 13: ... program 7 Edit program 8 Set program Set program 1 Start step 0 100 End step 0 100 Step time 0 255 Save Set program 2 Same as Set program 1 Set program 3 Set program 4 Set program 5 Set program 6 Set program 7 Set program 8 Run Running program Fixed scene Scene 001 100 Service Error list Adjust Pan 5 00 Tilt 5 00 Rotatable lens 5 00 Factory Default Adjust default Firmware update ...

Page 14: ...st 251 255 99 100 Unused range 4 Red 0 255 0 100 5 Green 0 255 0 100 6 Blue 0 255 0 100 7 White 0 255 0 100 8 Macro color 0 1 0 1 2 254 1 99 Shadow 255 100 9 Pan 0 255 0 100 10 Pan fine 0 255 0 100 11 Tilt 0 255 0 100 12 Tilt fine 0 255 0 100 13 Rotatable lens 0 127 0 49 128 135 50 52 136 231 53 90 232 255 91 100 14 Rota sp 0 255 0 100 15 Fixture control 0 9 0 3 10 14 4 5 15 19 6 7 20 24 8 9 25 29...

Page 15: ...ctive n 0 15 3 7 11 15 19 63 219 221 85 86 ID is 4 n 4 effective n 0 15 4 8 12 16 20 64 222 224 87 88 ID is 5 n 1 effective n 0 12 1 6 11 16 21 61 225 227 88 89 ID is 5 n 2 effective n 0 12 2 7 12 17 22 62 228 230 89 90 ID is 5 n 3 effective n 0 12 3 8 13 18 23 63 231 233 90 91 ID is 5 n 4 effective n 0 12 4 9 14 19 24 64 234 236 91 92 ID is 5 n 5 effective n 0 11 5 10 15 20 25 60 237 239 93 94 ID...

Page 16: ...xture from the main power before you start with the maintenance cleaning and maintenance specifications Voltage 240VAC 50 60Hz Power 91W LED chips 6x RGBW 4 in 1 LED chip Lens degree Standard 1 5 Beam angle Minimum 6 maximum 51 Color RGBW Strobe 1 30 times second electronic strobe and random strobe Pan 540 Tilt 180 Control mode DMX512 RDM ready Channel Standard CH11 extended CH17 Display menu 2 4 ...

Page 17: ...WWW CLF LIGHTING COM CLFLIGHTING beam 6 ...