WARNING!

Read the safety precautions in this section before 

installing, powering, operating or servicing this 

product.

The following symbols are used to identify important safety information on the product and in this manual:

DANGER!

 

Safety hazard. 

Risk of severe

injury or death.

DANGER!

 

Hazardous 

voltage. Risk of 

lethal or severe 

electric shock.

WARNING!

 

Fire hazard.

WARNING!

 

LED light 

emission. Risk of 

eye injury.

WARNING!

 

Burn hazard. Hot 

surface. Do not 

touch.

WARNING!

 

Wear protective 

eyewear. 

WARNING!

 

Refer to user 

manual.

Warning! Risk Group 2 (high risk) LED product according to EN 62471. Do not look into the beam at a 
distance of less than 0.5 meters from the front surface of the product. Do not view the light output with optical 
instruments or any device that may concentrate the beam. 

This product is for professional use only. It is not for household use.
This product presents risks of severe injury or death due to fire and burn hazards, electric shock and falls.

Rea

d this manual before installing, powering or servicing the fixture, follow the safety precautions listed  below and 

observe all warnings in this manual and printed on the fixture. If you have questions about how to operate the fixture 
safely, please contact your supplier.

PROTECTION FROM ELECTRIC SHOCK

• 

Disconnect the fixture from AC power before removing or installing any cover or part and when not in use.

• 

Always ground (earth) the fixture electrically.

• 

Use o

nly a source of AC power that complies with local building and electrical codes and has both overload and 

ground-fault (earth-fault) protection.

• 

Befo

re using the fixture, check that all power distribution equipment and cables are in perfect condition and rated 

for the current requirements of all connected devices.

• 

Power

 input and throughput cables must be rated 20 A minimum, have three conductors 1.5 mm² (16 AWG) 

minimum conductor size and an outer cable diameter of 5 - 15 mm. Cables must be hard usage type (SJT or 
equivalent) and heat-resistant to 90° C minimum.

• 

Use 

only PowerCON TRUE 1 

®

 cable connectors to connect to power input sockets. Use only PowerCON TRUE 1 

®

 cable connectors to connect to power through put sockets.

• 

I

sola

te the fixture from power immediately if the power plug or any seal, cover, cable, or other component  is 

damaged, defective, deformed, wet or showing signs of overheating. Do not reapply power until repairs have been 

completed.

• 

Refer 

any service operation not described in this manual to a qualified technician.

• 

Socket o

utlets used to supply fixture fixtures with power or external power switches must be located near the 

fixtures and easily accessible so that the fixtures can easily be disconnected from power.

Summary of Contents for Serius

Page 1: ...manual WWW CLF LIGHTING COM V1 O JUNE 2019 serius ...

Page 2: ...ssion 6 Physical installation 7 Fastening the fixture to a flat surface 7 Outdoor IP rated fixtures 8 Condensation moisture inside housing 8 Fixtures temperature specification 8 Setup 9 Control panel and menu navigation 9 DMX Address 9 control panel 10 Personality 10 Art Net 10 Information 10 Factory Reset 10 Dimmer curve 11 Onboard control menus 12 DMX protocol 14 Specifications 17 WWW CLF LIGHTI...

Page 3: ...Dimensions All dimensions are in millimeters WWW CLF LIGHTING COM 1 All dimensions are in millimeters 1000 278 113 115 33 ...

Page 4: ...y please contact your supplier PROTECTION FROM ELECTRIC SHOCK Disconnect the fixture from AC power before removing or installing any cover or part and when not in use Always ground earth the fixture electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Before using the fixture check that all p...

Page 5: ... of the fixture without protective eyewear such as shade 4 5 welding goggles At less than this distance the LED emission can cause eye injury or irritation At distances of 0 5 meters and above light output is harmless to the naked eye provided that the eye s natural aversion response is not overcome Do not look at LEDs with magnifiers telescopes binoculars or similar optical instruments that may c...

Page 6: ...and the selected functions 3 Battery Display Acces menu without power 4 DMX IN 5 pin DMX input 5 DMX OUT 5 pin DMX output 6 POWER IN To connect to the mains supply 7 POWER OUT power out for daisy chain 8 ETHERNET Artnet 9 FUSE T10A Protect the unit from damage overcurrent 10 PUSH BUTTON 1 Head lock button Before the fixture is powered on please UNLOCK the head 11 PUSH BUTTON 2 When the fixture is ...

Page 7: ...Warning Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power Important Do not insert or remove live PowerCON TRUE 1 connectors to apply or cut power as this may cause arcing at the terminals that will damage the connectors Important Do not use an external dim...

Page 8: ...e 2 Connect the DMX output of the fixture closest to the controller to the DMX input of the next fixture and continue connecting fixtures output to input Relaying power to other devices Warning Do not connect more than 7 fixtures in total to AC mains power in one interconnected chain Power can be relayed to another device via the PowerCON TRUE 1 throughput socket If you daisy chain the fixtures in...

Page 9: ...least 10 times the weight of all fixtures and equipment to be installed on it Warning The supporting surface must be hard and flat or cooling may be blocked which will cause overheating Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the safety cable attachment point see Fixture overview if the f...

Page 10: ...age to aging materials and affect the coated surface i e stainless steel Rubber sealings will be negatively affected after long term UV exposure and should be checked by qualified service technicians over time Tighten screws too hard will also affect the IP rating solid object Moisture IP Ingress Protection 2 2 Protected against a solid object greater than 50mm such as a hand Protected against a s...

Page 11: ...lues To enter a menu select a function or apply a selection press ENTER To escape a function or move back one level in the menu structure press MODE DMX ADDRESS The DMX address also known as the start channel is the first channel used to receive instructions for the controller For independent control each fixture must be assigned its to a separate channel The DMX address can be configured by using...

Page 12: ...r ArtNet Port Setup channels mode press the ENTER button to store When choose Ethernet IP Setup use the UP DOWN button to select IP Address or Subnet Mask When choose Art Net Port Setup use the UP DOWN button to select Net Subnet or Universe Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode ArtNet to DMX To select Artnet to DMX press the ENTER button to ...

Page 13: ...ity appears to be linear as DMX value is increased Squrare Law Light intensity control is finer at low levels and coarser at high levels Inverse Square Law Light intensity control is coarser at low levels and finger at high levels S curve Light intensity control is finger at low levels and high levels and coarser at medium levels ...

Page 14: ... Fixture Settings Invert Pixel Order Disable Enable Artnet to DMX Disable Enable Light Mode Color Calibration Disable Enable Max White Balance Red Green Blue Dimmer Curve Optically linear Square Law Inverse Square LAw S Curve Dimmer Speed Smooth Fast Invert Tilt Disable Enable Tilt Feedback Disable Enable BI O Tilt Moving Disable Enable Fan Mode Silent Auto Auto Test Manual Mode Tilt Dimmer Strobe...

Page 15: ...Chinese Temperature Unit C F Display Warning Disable Enable Fixture Information LED Temperature 40 C 125 C Fixture Usage Time 0 99999 LED Light Time 0 99999 Firmware Version APP 1 0 Boot 1 0 Reset Functions All No Yes Tilt No Yes Zoom No Yes Factory Setting Yes No Manual Mode Green Blue White Zoom ...

Page 16: ...dom strobe effect slow to fast 224 255 Shutter open 7 Macro 000 008 No function 009 038 Macro 1 039 068 Macro 2 069 098 Macro 3 099 128 Macro 4 129 158 Macro 5 159 187 Macro 6 188 255 Macro 7 8 Foreground Color 000 255 9 Background Color 000 255 10 RED 000 255 11 GREEN 000 255 12 BLUE 000 255 13 WHITE 000 255 14 Special Function 000 060 No function 061 080 Black out when Tilt moving 081 100 Disabl...

Page 17: ...Shutter open 192 223 Random strobe effect slow to fast 224 255 Shutter open 9 LED1 RED 000 255 0 100 10 LED1 GREEN 000 255 0 100 11 LED1 BLUE 000 255 0 100 12 LED1 WHITE 000 255 0 100 13 LED2 RED 000 255 0 100 14 LED2 GREEN 000 255 0 100 15 LED2 BLUE 000 255 0 100 16 LED2 WHITE 000 255 0 100 17 LED3 RED 000 255 0 100 18 LED3 GREEN 000 255 0 100 19 LED3 BLUE 000 255 0 100 20 LED3 WHITE 000 255 0 10...

Page 18: ... 255 0 100 44 LED9 WHITE 000 255 0 100 45 LED10 RED 000 255 0 100 46 LED10 GREEN 000 255 0 100 47 LED10 BLUE 000 255 0 100 48 LED10 WHITE 000 255 0 100 49 LED11 RED 000 255 0 100 50 LED11 GREEN 000 255 0 100 51 LED11 BLUE 000 255 0 100 52 LED11 WHITE 000 255 0 100 53 LED12 RED 000 255 0 100 54 LED12 GREEN 000 255 0 100 55 LED12 BLUE 000 255 0 100 56 LED12 WHITE 000 255 0 100 57 Special function 00...

Page 19: ... color RGBW LED color temperature LED CRI level Quantity of LED 12 Dimming frequency Dimmer resolution 16bit Optical Beam angle Zoom 3 5 38 Photometric Output 5M 11009 LUX 3 5 2752 LUX 3 5 Output 10M 553 LUX 38 61 LUX 38 Heat management Cooling type Regulated fans MAX ambient temp Ta max 40 MIN ambient temp Ta min 0 MAX Surface temperature 65 Menu Auto program Yes Static color Yes Manual calibrati...

Page 20: ...ata input artnet SACN RJ45 Hardware Interface OLED display with battery backup Software upload method Via DMX input Installation IP rating IP22 Housing Safety attachment point yes Physical Net product weight 17 KG Machine dimensions length 1000 mm Machine dimensions depth 113 mm Machine dimensions height 278 mm Accessories included items User manual power cord Approvals Approved certifications CE ...