Outdoor IP-rated fixtures

CLF

 products are applied to official classified IP norm levels. For this product the IP rate is IP65 when using the covers for the chassis 

parts. IP65 means according classified norm: shielded against dust and pressurized water from any side.  Typical use for outdoor rated 
stage events with normal weather acceptance. So no heavy rain, because then the water pressure over exceeds the IP norm.

Condensation/moisture inside housing

Because

 of high humidity levels during production condensation can occur inside the housing. This is mostly visible on the coldest parts of 

the fixture, like the front glass or display. To prevent this problem we work with special conditioned areas for outdoor fixtures. Because of 
the breathing air valves it is still possible to get humidity inside the fixture. This will evaporate slowly. Do not put wet fixtures in a flightcase, 
this will help humidity enter the fixture.

Fixtures temperature specification

Make sure the fixture is used within its working temperature range. Outside this range we cannot guarantee correct operation.

Temporary usage:

Stage event equipment is designed with temporary use in mind. Our product purpose is for theatre, festival, (disco) clubs and indoor & 
outdoor concerts.  Long term use is possible but keep in mind that it can bring damage to aging materials and affect the coated surface ( 
i.e. stainless steel). Rubber sealings will be negatively affected after long-term UV exposure and should be checked by qualified service 
technicians over time. 

 

Tighten screws too hard will also affect the IP-rating.

solid object

Moisture

1
2
3
4
5
6
7
8

IP

Ingress 

Protection

6 5

Protected against a solid object greater 

than 50mm such as a hand.

Protected against a solid object greater 

than 12.5mm such as a finger.

Protected against a solid object greater 

than 2.5mm such as a screwdriver.

Protected against a solid object greater 

than 1mm such as a wire.

Dust protected. Limited ingress of 

dust permitted. Will not interfere 

with operation of the equipment. 

Dust tight. No ingress of dust. 

Protected against vertical falling drops of 

water. Limited ingress permitted.

Protected against water splashes from 

all directions. Limited ingress permitted.

Protected against vertical falling drops 

of water with enclosure tilted up to 15 

degrees from the vertical. Limited 

ingress permitted. 

Protected against sprays of water up 

to 60 degrees from the vertical. 

Limited ingress permitted. 

Protected against jets of water. 

Limited ingress permitted.

Protected against powerful jets of water. 

Limited ingress permitted.

Protected against the effects of 

immersion in water between 15cm and 

1m for 30 minutes.

Protected against the effects of 

immersion in water under pressure for 

long periods. 

1
2
3
4
5
6

21.0

Summary of Contents for HERA

Page 1: ...manual V1 0 March 2018 WWW CLF LIGHTING COM HERA H E R A ...

Page 2: ...ixture to a flat surface 7 Setup 8 Control panel and menu navigation 8 DMX address setting 8 Control Mode 9 Static Color options 10 Auto Show 11 Master Slave 11 Personality 11 Dimmer speed 11 Dimmer curve 11 Key Lock 11 W DMX 11 Calibration 11 Refresh rate 11 LCD brightness 11 DMX HOLD 11 Dimmer mode 12 Information 12 Software type 12 Usage time 12 Temperature 12 UID 12 Factory reset 12 DMX protoc...

Page 3: ...Dimensions All dimensions are in millimeters WWW CLF LIGHTING COM 1 0 hera 106 260 290 Φ203 180 ...

Page 4: ...d observe all warnings in this manual and printed on the fixture If you have questions about how to operate the fixture safely please contact your supplier PROTECTION FROM ELECTRIC SHOCK l Disconnect the fixture from AC power before removing or installing any cover or part and when not in use l Always ground earth the fixture electrically l Use only a source of AC power that complies with local bu...

Page 5: ...the optional CLF Hera filters l Do not modify the fixture in any way not described in this manual l Do not use fixture on a dimmer PROTECTION FROM INJURY l Do not look continuously at LEDs from a distance of less than 3 meters from the front surface of the fixture without protective eyewear such as shade 4 5 welding goggles At less than this distance the LED emission can cause eye injury or irrita...

Page 6: ... cable attachment point LCD Display 5P DMX input 5P DMX output AC mains power throughput AC mains power input G Clamp with Quicklock 875760 Optional Omega bracket with Quicklock 520114 Optional 3P DMX input optional CLF 13 453 3P DMX output optional CLF 13 454 HERA ...

Page 7: ...or circuit breaker and ground fault earth fault protection Warning Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power Important Do not insert or remove live connectors to apply or cut power as this PowerCON TRUE 1 may cause arcing at the terminals that will...

Page 8: ...ust be used to connect the first fixture to AC mains power connectors must be used to draw AC mains power from the fixtures power throughput PowerCON TRUE 1 sockets and yellow connectors must be used to supply power at the fixture s power input PowerCON TRUE 1 sockets No matter what the AC mains power voltage is do not connect more than ten the fixture in total including the first fixture to AC ma...

Page 9: ...face can support at least 10 times the weight of all fixtures and equipment to be installed on it Warning The supporting surface must be hard and flat or air vents in the base may be blocked which will cause overheating Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the safety cable attachment p...

Page 10: ...s can be configured by using the DMX ADDRESS menu in the control panel For setting the DMX address press ENTER before you can change the address The main screen will show a dot and the backlight will be switched off when a DMX signal is detected The fixture is fully RDM ready So when you are using a RDM ready console you can address the unit and read out its complete status For RDM functions pleas...

Page 11: ...ty WWW CLF LIGHTING COM 9 0 Control mode DMX control mode is selected in the CONTROL MODE menu The fixture has 9 DMX control modes 4ch 5ch 6ch 7ch 8ch 11ch 13ch Dimmer RGBW A UV Strobe CCT Macro color Effect Dimmer Auto speed Function set ...

Page 12: ...lor Mix your own color with each RGBWAP value seperately R Red RB Red Blue BW Red White G Green GB Green Blue RGW Red Green White B Blue RGB Red Green Blue RBW Red Blue White W White RW Red White GBW Green Blue White RG Red Green GW Green White RGBW Red Green Blue White Red 000 255 Dimmer Red Green 000 255 Dimmer Green Blue 000 255 Dimmer Blue White 000 255 Dimmer White Amber 000 255 Dimmer Amber ...

Page 13: ...gram 6 7 Auto 7 Auto program 7 17 Program 7 pre program 7 8 Auto 8 Auto program 8 18 Program 8 pre program 8 9 Auto 9 Auto program 9 19 Program 9 pre program 9 10 Auto 10 Auto 1 10 cycle program 20 Program 10 pre program 10 Here you can set all functions for the fixture personality Dimmer Speed Normal Smooth 1 Smooth 2 Smooth 3 Smooth 4 Dimmer curve linear Square law INV Square law S Curve Special...

Page 14: ...tensity control is coarser at low levels and finer at high levels l S CURVE light intensity control is finer at low levels and high levels and coarser at medium levels l Special the light intensity was linear increase with DMX value and light intensity control is finer at low level with DMX values decrease the dimmer speed will also has effect on it Whichever DIMMER CURVE option you select you can...

Page 15: ...2 Saturation 000 255 0 100 3 Value 000 255 0 100 HSI Function Value Setting Remark 1 Hue 000 255 0 100 2 Saturation 000 255 0 100 3 Intensity 000 255 0 100 4 CH Function Value Setting Remark 1 Red 000 255 0 100 2 Green 000 255 0 100 3 Blue 000 255 0 100 4 White 000 255 0 100 5 CH Function Value Setting Remark 1 Dimmer 000 255 0 100 2 Red 000 255 0 100 3 Green 000 255 0 100 4 Blue 000 255 0 100 5 W...

Page 16: ...en Strobe 1 fast slow Shutter open Strobe 2 opening pulse fast slow Shutter open Strobe 3 closing pulse fast slow Shutter open Strobe 4 random strobe fast slow Shutter open Strobe 5 random opening pulse fast slow Shutter open Strobe 6 random closing pulse fast slow Shutter open Strobe 7 burst pulse fast slow Shutter open Strobe 8 random burst pulse fast slow Shutter open Strobe 9 sine wave fast sl...

Page 17: ...low Shutter open 7 CCT 000 009 010 255 No function 10000K 2500K 8 Color wheel 000 009 010 255 No Function Color wheel rotation effect 9 Auto program 000 009 010 019 020 029 100 109 110 119 120 129 200 255 No function Auto program 1 Auto program 2 Auto program 10 AUTO 1 10 cycle Custom program 1 Custom program 2 Custom program 10 10 Speed 000 1 255 No function AUTO Speed or Dimmer Speed 11 Fixture ...

Page 18: ...obe 10 burst fast slow Shutter open 9 CCT 000 009 010 255 No function 10000K 2500K 10 Color wheel 000 004 005 255 No Function Color wheel rotation effect 11 Auto program 000 009 010 019 020 029 100 109 110 119 120 129 200 255 No function Auto program 1 Auto program 2 Auto program 10 AUTO 1 10 cycle Custom program 1 Custom program 2 Custom program 10 12 Speed 000 1 255 No function AUTO Speed or Dim...

Page 19: ... Macro color 9 Effect 10 Speed 11 Function set 13CH 1 Dimmer 2 Red 3 Green 4 Blue 5 White 6 Amber 7 UV 8 Strobe 9 CCT 10 Macro color 11 Effect 12 Speed 13 Function set HSV 1 Hue 2 Saturation 3 Value HSI 1 Hue 2 Saturation 3 Intensity 3 PERSONALITY Dimmer Speed Normal Default Normal Smooth 1 Smooth 2 Smooth 3 Smooth 4 Dimmer curve linear Default linear Square law INV Square law S Curve Special Key ...

Page 20: ...AUV CCT 2500K 3000K 4000K 5000K 6000K 7000K 8000 9000K 10000K Default 6000K Manual color Dimmer 0 255 Red 0 255 Green 0 255 Blue 0 255 White 0 255 Amber 0 255 UV 0 255 Strobe 0 20 Default Dimmer 255 Red 255 Green 255 Blue 255 White 255 Amber 255 UV 255 Strobe 0 5 AUTO AUTO 1 10 Speed 0 20 Default AUTO 1 Programe 1 10 6 EDITOR Programe 01 10 Scene 01 30 Red 0 255 Green 0 255 Blue 0 255 White 0 255 ...

Page 21: ...r CLF 14 017 9 Power supply CLF 14 015 10 Power supply support bracket CLF 14 007 11 Case body CLF 14 001 12 Display board CLF 17 005 13 Display sticker CLF 17 004 14 Acrylic display support CLF 14 012 15 PowerCON TRUE1 input socket CLF 14 027 16 PowerCON TRUE1 output socket CLF 14 028 17 DMX 5 pin male chassis part waterproof CLF 14 032 18 DMX 5 pin female chassis part waterproof CLF 14 031 19 Va...

Page 22: ... materials 100 mm from fixture Minimum distance to illuminated surfaces 200 mm from fixture Connections AC power input PowerCON TRUE 1 input socket AC power throughput PowerCON TRUE 1 output socket DMX data in out 5 pin locking XLR 3 pin optional with CLF 13 453 CLF 13 454 Electrical AC power 100 240 V nominal 50 60 Hz Maximum total power consumption 105 W Power supply unit Auto ranging electronic...

Page 23: ... possible but keep in mind that it can bring damage to aging materials and affect the coated surface i e stainless steel Rubber sealings will be negatively affected after long term UV exposure and should be checked by qualified service technicians over time Tighten screws too hard will also affect the IP rating solid object Moisture 1 2 3 4 5 6 7 8 IP Ingress Protection 6 5 Protected against a sol...

Page 24: ...WWW CLF LIGHTING COM 22 0 NOTE ...

Page 25: ...Hera WWW CLF LIGHTING COM CLFLIGHTING ...

Reviews: