WWW.CLF-LIGHTING.COM
cleaning and maintenances
• To ensure that the fixture works normally, always keep it clean. We recommend to clean the fans and ventilation inlet frequently. The lens
and dichroic color filters should also be cleaned regularly to maintain an optimum light output. Do not use any type of
chemicals to clean the dichroic color filters, it will damage the fixture.
• Disconnect the power supply when you start maintenace. Please let the fixture cool down for at least 10 minutes. If you need to replace
the lamp, please wait for at least 30 minutes to let the lamp cool down completely to prevent burn injuries.
• Please inspect the lens or other moving parts regularly and keep them clear and static free. If you find anything damaged or loose, you
must replace the fixture or repair the fixture in order to avoid accidents.
• The light uses a strong cooling system. Please clean the fan inlet frequently.
troubleshooting
It is recommended to check the following list when troubleshooting. Any unsolutioned problems should always be handle by a qualified
person. Disconnect the power supply before opening the fixture.
Lamp off
• Please check if the lamp is installed properly.
• Please check the connection of the power supply or switch is ok.
• Please check the lamp hours of the lamp. If it is too much, please replace the lamp.
• Please check if the power supply is between 100 and 240 VAC.
• Please check the connection of the trigger circuit inside the base has a loose contact.
• Check menu “information” → “fan speed / voltage → fan1, fan2 & fan3” for fanspeed. If the fan speed is above 500RPM or
below 500RPM the lamp does not turn on, replace the fan.
• Please check if the temperature switch is damaged.
• Enter the menu “information” then select “temperature” to see whether the temperature display board is too high or has no temperature
information at all.
The light beam is not bright or not uniform
• When the lamp hours are consumed, please change bulb.
• Please check the reflector parts. Keep them clear but do not use chemicals.
• Enter the menu “service options” to choose “calibration” to enter the “Color” and “Gobo” calibration.
The light shadow is blurred
• Please check the electric focus inside.
• Please check the focus and lens for dirt. After cleaning, please add some
temperature durable oil on the moving parts.
The light works interrupted
• Please check if the fan works normally.
• Please check whether fan covers are clean.
• Please check if the lamp is not at the end of the usage time.
• Please check if the power supply is between 100 and 240 VAC and if the connection of the power supply or the circuit are good.
• Please check if the temperature switch is correct.
21.0