Clevertest and Clevertest Plus 

 

Refer to the supplementary operation guide supplied with the Product.

 

 

 

After Power ON, the Status LED on a Clevertest Plus enabled fitting will display a rapid Green or Red 
flashing for a period up to 2 minutes. 

 

4HR:

 CTP will only test for the 2 hours (first test) and 90 minutes duration. 4 hours testing would only be 

facilitated as a Manual Discharge Test. 

 

Zoneworks, HIVE (HV/HVG) and DATA Monitored Options

 

Fittings with part numbers -ZW

, -HV, -HVG, -DATA 

are fitted with Zoneworks communications modules 

(nodes).  These  fittings  are  monitored  using  either  Powerline  Carrier  Technology  that  utilize  the  power 
cable to provide data communication, RF transceiver modules operating in the ISM band or a dedicated 
data cable to/from data routers installed on a dedicated data trunk connected to a central Server (can also 
be  connected  via  Ethernet/Internet/Fibre).  Zoneworks  software  on  the  server  is  used  to  monitor, 
coordinate testing and collate test data from each fitting. Zoneworks Fittings can be commissioned by a 
single push of the test switch or by scanning the supplied barcode. The LED Test Switch indicator provides 
a multifunction indication of the status of the fitting during testing and normal operation: 

Option 

State 

LED Operation 

ZW, HV, HVG, 
DATA 

Commissioned 

LED on Solid (Green) 

ZW, DATA 

Un-commissioned 

Batt plugged-in:

 yellow 1s, green 1s 

Batt unplugged:

 red 1s, off 1s 

HV, HVG 

Un-commissioned 
With network connectivity 

Batt plugged-in:

 yellow 1s, green 1s 

Batt unplugged:

 red 1s, off 1s 

HV, HVG 

Un-commissioned 
Without network connectivity 

Batt plugged-in:

 yellow 250mS, green 250mS, 

yellow 250mS, green 250mS, green 1s 

Batt unplugged:

 red 250mS, off 250mS, red 

250mS,off 250mS, off 1s 

ZW, DATA 

Emergency Light Test In Progress 

LED flashes at yellow 5s , 0ff 1s 

HV, HVG 

Emergency Light Test In Progress 

LED flashes at yellow 1s , 0ff 1s 

In the case of the DATA version a 2-way 

“figure 8” cable and terminal block facilitates the connection to 

the DATA network via a multi-drop bus (daisy chain connection).  For further information of installation of 
a Zoneworks system, please refer to the Zoneworks Users Guide and Commissioning Guide (incl. DATA 
version).  

 

DALI EM Option 

Cleverfits with part numbers -DALI are fitted with DALI modules (nodes) that facilitate connection and 
integration to 3rd Party Lighting Control Systems.  Before installing the fitting please confirm that the 
Lighting Control System has the capability to monitor DALI Emergency Luminaires.  The fitting will be 
addressed and configured into the control system by the Lighting Control System Commissioning 
Technicians and not Clevertronics.   

State

 

LED Operation

 

Commissioned/ Un-commissioned 

LED on Solid (Green) 

Emergency Light Test in progress 

LED flashes at 1s On (Yellow) & 1s Off 

“IDENTIFY COMMAND” 

Lamp and Status LED Flash for 30 seconds

 

A 2-

way “figure 8” cable and terminal block facilitates the connection to the DALI network.  DALI 

connections are marked as Da Da.  

 

 
 
 
 

 

 

LP™ Cleverfit LED Exit

 

Installation & Maintenance Instruction Leaflet

 

 

Victoria (Head Office & Manufacturing) 

Website

www.clevertronics.com.au

 

Email

[email protected]

 

Phone

: +61 3 9559 2700  

Fax

: +61 3 9559 2799 

 

New South Wales

 

Phone

: +61 2 8805 6400 

Fax

: +61 2 8805 6444 

Queensland  

Phone

: +61 7 3442 9700 

Fax

: +61 7 3442 9777 

 

South Australia/Northern Territory  

Phone

: +61 8 8301 8800 

Fax

: +61 8 8351 8286 

 

Western Australia  

Phone

: +61 8 9207 0000 

Fax

: +61 8 9207 0088 

 

New Zealand 

Phone

: +64 800 548 448

 

Designed in Australia to comply with the 
requirements of AS2293.3: 2005 and AS/NZS 
CISPR15: 2017 

NOTE: Standard product codes with this symbol        are 
enabled with Clevertest Plus capability.  Please refer to 
the operation guide supplied with the product for details.

 

 
Models:  

 

 

 
CCFLED-xx-vv-ss-zz  CleverFit Exit

 

CCFLED-TH-xx-yy-zz  CleverFit Theatre Exit 

Testing: 

 

 

 

Options:

 

 

Manual Test 

 

xx = Blank 

 

 

4 Hour Runtime 

zz= 4HR 

Zoneworks

 

xx = ZW 

 

 

Black in Colour 

ss = BLK 

Z/W DATA  

 

xx = DATA 

 

 

Running Man

 

yy = R

 

Zoneworks HIVE

 

xx = HV/HVG

  

 

Running Man Left Arrow

 

yy = RL

 

DALI Registered.     

 

xx = DALI 

 

 

Running Man Right Arrow

 

yy = RR

 

Clevertest 

xx = CT   

 

 

Double sided DS Running Man

 

yy = DS-R

 

 

 

 

 

Double sided Running Man Arrow

 

yy = DS-RAOW

 

 

 

 

 

Exit

 

yy = E

 

 

 

 

 

Tamperproof

 

vv =TP

 

 
 
 

(NOTE: -CT Products supplied with the Clevertest Plus Symbol         are activated with Clevertest 
PLUS capability. Please refer to the operation guide supplied with the product for details). 

 
Spare Parts:

 

1550105

 

BATT:LP 3.2V 1100mAh 260mm lead,no BRKT.

 

1550090

 

BATT: LP 3.2V 3200mAh 390mm lead, noBRKT (-4HR)

 

8002710

 

PCA:DurisLED Strip Clvrft Pro CT10276-D3 

8002329

 

PCA:CCFLED Driver CT10164-L6 6C43 (-DALI, -HV) 

8002348 

PCA:CCFLED Driver CT10164-L6 6C43 (CTP, -ZW) 

 

Important: 

It is illegal for anyone, except for a licensed electrician to install or maintain this product. Before 
installation, ensure that the electricity supply has been switched off and isolated. Installation must be 
carried out in accordance with the relevant Australian and International Standards. 

 

 

 

 

 

 

Reviews: