Refer to the supplementary operation guide supplied with the Product.

 

 

 

After Power ON, the Status LED on a Clevertest Plus enabled fitting will display a rapid Green or Red 
flashing for a period up to 2 minutes. 
 

The glass cover will require removal to gain access to the Test/Status Switch and LED. 
Maintained fittings ((LWPLIFE

M

-PRO-xx-yy-WM-ss)) cannot be scanned with a camera using the 

CleverSparky App as the maintained light source interferes with the camera scanning function. To register 
the fitting manually enter the serial number from the QR code and visually read the test result and enter 
manually into CleverSparky. 
 

Zoneworks and DATA Monitored Options

 

Luminaires  with  part  numbers 

-ZW,  -DATA 

are  fitted  with  Zoneworks  communications  modules 

(nodes).These  fittings  are  monitored  using  either  Powerline  Carrier  Technology  that  utilising  the  power 
cable  to  provide  data  communication  or  a  dedicated  data  cable  to/from  data  routers  installed  on  a 
dedicated data trunk connected to a central Server (can also be connected via Ethernet/Internet/Fibre). 
Zoneworks software on the server is used to monitor, coordinate testing and collate test data from each 
Lifelight. Zoneworks Lifelights can be commissioned by a single push of the test switch or scanning of the 
supplied barcode. The LED Test Switch indicator provides a multifunction indication of the status of the 
Lifelight during testing and normal operation: 

State

 

LED Operation

 

Commissioned 

LED on Solid (Green) 

Un-commissioned 

LED flashes at 0.5Hz (0.5s Green, 0.5s Yellow) 

Emergency Light Test In Progress 

LED flashes at 3s On (Yellow) & 0.5s Off 

 
In the case of the DATA version a 2-

way “figure 8” cable and terminal block facilitates the connection to the 

DATA network via a multi-drop bus (daisy chain connection).    For further information of installation of a 
Zoneworks LW system, please refer to the Zoneworks Users Guide and Commissioning Guide (incl. DATA 
version)   
 

DALI EM Option

 

Lifelights  with  part  numbers 

-DALI 

are  fitted  with  DALI  modules  (nodes)  that  facilitate  connection  and 

integration  to  3

rd

  Party  Lighting  Control  Systems.  Before  installing  the  -DALI  please  confirm  that  the 

Lighting  Control  System  has  the  capability  to  monitor  DALI  Emergency  Luminaires.  The  -DALI  will  be 
addressed  and  configured  into  the  control  system  by  the  Lighting  Control  System  Commissioning 
Technicians and not Clevertronics.     

State

 

LED Operation

 

Commissioned/ Un-commissioned 

LED on Solid (Green) 

Emergency Light Test in progress 

LED flashes at 1s On (Yellow) & 1s Off 

“IDENTIFY COMMAND” 

Lamp and Status LED Flash for 30 seconds 

 
A 2-

way “figure 8” cable and terminal block facilitates the connection to the DALI network OR a 5/6way 

“structured wiring system” lead and plug facilitating the power and DALI connection.    DALI connections 
are marked as Da Da.   

 

Wall Mount Weatherproof Lifelight Pro Emergency Luminaire 

 

Installation & Maintenance Instruction Leaflet

 

Victoria (Head Office & Manufacturing) 

195 Chesterville Rd 
Moorabbin VIC 3189   

Phone:

 +61 3 9559 2700   

Fax:

 +61 3 9559 2799 

New South Wales

 

Phone:

 +61 2 8805 6400 

Fax:

 +61 2 8805 6444

 

Queensland

   

Phone:

 +61 7 3442 9700 

Fax:

 +61 7 3442 9777 

 

South Australia/Northern Territory

   

Phone:

 +61 8 8301 8800 

Fax:

 +61 8 8351 8286 

 

Western Australia

   

Phone:

 +61 8 9248 3720 

Fax:

 +61 8 9248 3725 

 

New Zealand 

Phone:

 +64 800 548 448

 

 
 
 
 

 

 
Designed in Australia to comply with the requirements 
of AS2293.3: 2005 and AS/NZS CISPR15: 2017 

NOTE: Standard product codes with this symbol              are 
enabled with Clevertest Plus capability.    Please refer to the 
operation guide supplied with the product for details.

 

 

 

 

Models:

 

LWPLIFEz-PRO-xx-yy-WM-ss

 

Testing: 

 

 

 

Options:

 

 

Manual Test 

 

yy = Blank   

 

Maintained Operation 

z = M 

Zoneworks

 

yy = ZW 

 

 

Custom Colour 

ss 

Z/W DATA   

 

yy = DATA   

 

Switch Active 

xx = SA 

DALI Comp.         

 

yy = DALI 

 

 

 

 

Clevertest 

yy = CT     

 

 

 

 

 

(NOTE: -CT Products supplied with the Clevertest Plus Symbol        are activated with 
Clevertest  PLUS  capability.  Please  refer  to  the  operation  guide  supplied  with  the 
product for details). 

 

Spare Parts:   

1530230   

 

Replacement Battery 

1100835   

 

Replacement Emergency LED Board 

AUM01370040001   

Replacement Emergency Driver 

AUM01370320001                      Replacement Emergency Driver 

 

Important:

 

It is illegal for anyone, except for a licensed electrician to install or maintain this product. Before 

installation, ensure that the electricity supply has been switched off and isolated. Installation must be 

carried out in accordance with the relevant Australian and International Standards. 

 

 

 

 

 

 

Reviews: