1942125
V2.1
19 July 2022
Clevertest and Clevertest Plus
Refer to the supplementary operation guide supplied with the Product.
After Power ON, the Status LED on a Clevertest Plus enabled fitting will display a rapid Green or Red
flashing for a period up to 2 minutes.
The glass cover will require removal to gain access to the Test/Status Switch and LED.
Maintained fittings ((LWPLIFE
M
-PRO-xx-yy-WM-ss)) cannot be scanned with a camera using the
CleverSparky App as the maintained light source interferes with the camera scanning function. To register
the fitting manually enter the serial number from the QR code and visually read the test result and enter
manually into CleverSparky.
Zoneworks and DATA Monitored Options
Luminaires with part numbers
-ZW, -DATA
are fitted with Zoneworks communications modules
(nodes).These fittings are monitored using either Powerline Carrier Technology that utilising the power
cable to provide data communication or a dedicated data cable to/from data routers installed on a
dedicated data trunk connected to a central Server (can also be connected via Ethernet/Internet/Fibre).
Zoneworks software on the server is used to monitor, coordinate testing and collate test data from each
Lifelight. Zoneworks Lifelights can be commissioned by a single push of the test switch or scanning of the
supplied barcode. The LED Test Switch indicator provides a multifunction indication of the status of the
Lifelight during testing and normal operation:
State
LED Operation
Commissioned
LED on Solid (Green)
Un-commissioned
LED flashes at 0.5Hz (0.5s Green, 0.5s Yellow)
Emergency Light Test In Progress
LED flashes at 3s On (Yellow) & 0.5s Off
In the case of the DATA version a 2-
way “figure 8” cable and terminal block facilitates the connection to the
DATA network via a multi-drop bus (daisy chain connection). For further information of installation of a
Zoneworks LW system, please refer to the Zoneworks Users Guide and Commissioning Guide (incl. DATA
version)
DALI EM Option
Lifelights with part numbers
-DALI
are fitted with DALI modules (nodes) that facilitate connection and
integration to 3
rd
Party Lighting Control Systems. Before installing the -DALI please confirm that the
Lighting Control System has the capability to monitor DALI Emergency Luminaires. The -DALI will be
addressed and configured into the control system by the Lighting Control System Commissioning
Technicians and not Clevertronics.
State
LED Operation
Commissioned/ Un-commissioned
LED on Solid (Green)
Emergency Light Test in progress
LED flashes at 1s On (Yellow) & 1s Off
“IDENTIFY COMMAND”
Lamp and Status LED Flash for 30 seconds
A 2-
way “figure 8” cable and terminal block facilitates the connection to the DALI network OR a 5/6way
“structured wiring system” lead and plug facilitating the power and DALI connection. DALI connections
are marked as Da Da.
Wall Mount Weatherproof Lifelight Pro Emergency Luminaire
Installation & Maintenance Instruction Leaflet
Victoria (Head Office & Manufacturing)
195 Chesterville Rd
Moorabbin VIC 3189
Phone:
+61 3 9559 2700
Fax:
+61 3 9559 2799
New South Wales
Phone:
+61 2 8805 6400
Fax:
+61 2 8805 6444
Queensland
Phone:
+61 7 3442 9700
Fax:
+61 7 3442 9777
South Australia/Northern Territory
Phone:
+61 8 8301 8800
Fax:
+61 8 8351 8286
Western Australia
Phone:
+61 8 9248 3720
Fax:
+61 8 9248 3725
New Zealand
Phone:
+64 800 548 448
Designed in Australia to comply with the requirements
of AS2293.3: 2005 and AS/NZS CISPR15: 2017
NOTE: Standard product codes with this symbol are
enabled with Clevertest Plus capability. Please refer to the
operation guide supplied with the product for details.
Models:
LWPLIFEz-PRO-xx-yy-WM-ss
Testing:
Options:
Manual Test
yy = Blank
Maintained Operation
z = M
Zoneworks
yy = ZW
Custom Colour
ss
Z/W DATA
yy = DATA
Switch Active
xx = SA
DALI Comp.
yy = DALI
Clevertest
yy = CT
(NOTE: -CT Products supplied with the Clevertest Plus Symbol are activated with
Clevertest PLUS capability. Please refer to the operation guide supplied with the
product for details).
Spare Parts:
1530230
Replacement Battery
1100835
Replacement Emergency LED Board
AUM01370040001
Replacement Emergency Driver
AUM01370320001 Replacement Emergency Driver
Important:
It is illegal for anyone, except for a licensed electrician to install or maintain this product. Before
installation, ensure that the electricity supply has been switched off and isolated. Installation must be
carried out in accordance with the relevant Australian and International Standards.