Installation:

 

The L10 Cleverfit Pro can be installed either Ceiling or Wall Mounted. The L10 Cleverfit Pro uses a “slide 

connect bracket base” that is mounted and wired into position first. The main body can be installed once 

the base is wired or later to avoid damage during the construction phase. Please follow the steps below 

to install the L10 Cleverfit Pro Exit: 

 

 

Disengage the slide connect bracket from the exit body. Position the base in the mounting position.  

 

Using the bracket as a guide, mark 2 holes for mounting and one for mains access. Then install the 

bracket using appropriate fixings (not supplied). 

 

Configure all the mounting parts and cable entry points as below (if required) and engage the body 

into the slide connect bracket. Connect mains and check that the L10 Cleverfit Pro Exit is 

Operational

 

If the CTP capabilities are activated, please affix the CTP Status Label to a visible surface and Four 

Segment Marking on the product will include an ‘’F’’ in third segment block.

 

 

 

 

 

Testing:

 

Once connected to the 240V mains supply, the unit must be allowed to charge the battery for at least 24 

hours. Conduct the following tests: 

 

For the first test, the emergency lamp must remain illuminated for at least 2 hours after 

disconnection from the mains supply. 

 

Subsequent tests require the unit to illuminate for at least 90 minutes. The results of all tests are 

required to be recorded in a service logbook, which is to be kept on-site at all times. If the unit fails 

to remain illuminated for the requisite time, remedial action must be taken to repair the situation 

and once completed, the unit must pass a subsequent test. For more specific information, please 

refer to the current edition of the AS 2293.3 Standard. 

 

Trouble Shooting: 

Below are a list of common problems and their possible causes. 

 

Fault:   The Green LED Test Switch indicator is not illuminated.

 

Check:   A.C. is connected and is turned on. 

 

Battery is connected 

Test Switch for damage. 

 

Fault:   Lamp does not illuminate in emergency mode. 

 

Check:   A.C. is connected. 

 

Lamp is correctly inserted. 

 

Battery is connected 

 

Fault:   Lamp illuminates in emergency mode, but only stays on for a short period. 

Check:  Battery has been allowed to charge for at least 24 hours. 

 

Battery for damage. 

 

 

Rated Emergency Lumen Output in accordance with AS2293.1, not applicable 

for –TH (theatre) version (refer to spacing tables for installation positions): 

 

 

 

Refer to the Technical Label for classification information.

 

Caution:

 

On many building sites, power circuits may be cut off in an uncontrolled and repetitive basis during 

construction. As a result, any Exit & Emergency Units, on these circuits, will have their batteries 

discharged or “cycled”. The battery in this fitting has been selected to give excellent long-life 

performance in a controlled AS2293 testing environment. Excessive battery cycling will reduce through-

life performance and may lead to premature battery failure. Battery warranty claims, as a result of such 

abuse, are specifically EXCLUDED from Clevertronics warranty terms. 