4
Connection Details:
All connections are via rubber
grommets on the sides of the box
and onto screw terminals located
on the printed circuit board.
• Caution:
When using the mic level outputs it is
recommended that the screen chassis
links be left in place to reduce the
possibility of hum pickup. However, care
must be taken when using both mic
level outputs to separate amplifiers not
to create earth loops within the system.
To prevent this from happening it may
be necessary to remove just one of the
screen chassis links and leave the other
intact.
Terminal Block
Designation
Description
TB1
C
70/100v signal common
70v
70v line signal input
100v
100v signal input
TB2
LINE 1 -
Line level signal output -
LINE 1 +
Line level signal
TB3
GND
Ground connection for mic 1 output
MIC 1
Mic level signal output -
MIC 1 +
Mic level signal
TB4
LINE 2 -
Line level signal output -
LINE 2 +
Line level signal
TB5
GND
Ground connection for mic 2 output
MIC 2 -
Mic level signal output -
MIC 2 +
Mic level signal