background image

www.cleveracoustics.co.uk

ZM4 4 Zone Mixer

  

User Manual

6

Operating instructions

9. Monitor level control: 

The monitor output volume is adjustable. Turn the level control anti clockwise to the lowest setting, 
or turn clockwise to adjust to the highest setting. This is used to control the volume for the 1W 8Ω 
loudspeaker output on the rear panel of the zone mixer. 

10. Zone output level control: 

The master volume control affects all audio sources within the amplifier, routed to the selected zone. 
Turn the level control anti clockwise to the lowest setting, or turn clockwise to adjust the overall output 
to the highest setting. Adjustments should be made gradually to avoid any sudden changes to the audio 
output.

11. Monitor output selector: 

To route one of the output zones to the monitor & headphone outputs, press the Monitor selection 
button. The monitor output volume can then be adjusted using the Monitor Volume Control.

12. Power LED: 

The Power LED will illuminate to indicate the zone mixer is powered on. If the power LED is not 
illuminated, check first the position of the on/off switch and then check the mains (including fuse) or DC 
power supply.

13. Power switch: 

On/Off control for the zone amplifier. Note: The on/off power switch does not have any control over the 
24V DC power input.

14. AC mains power input: 

Before connecting the amplifier to the local mains voltage outlet should be checked to ensure the 
available supply is 240V~AC 50Hz. This product is CLASS1 and requires a protective mains earth to be 
connected at all times. DO NOT remove or disconnect the earth. 

15. AC mains fuse: 

Disconnect from the mains power supply before attempting to replace the mains fuse. Replacement 
mains fuses must be the same rating as the original. T3.15AL 250V for 220-240V AC mains supply or 
T6.3AL 250V for 110-120V AC mains supply.

16. AC voltage selector: 

The ZM4 zone mixer features a dual voltage mains input. Disconnect the unit from the mains voltage 
power supply before attempting to change the mains input voltage. Care should be taken to select the 
appropriate mains input voltage to match that of the mains supply voltage. 

17. 24V DC power input: 

The ZM4 zone mixer features a 24V DC (600mA) power input for operation from a DC backup power 
supply. When both the DC and AC power inputs are connected, the ZM4 will operate using the AC mains 
power input and automatically switch to DC operation should the AC power supply fail. Care should be 
taken to observe the polarity and fuse requirements when connecting the DC power source.

 
 
 

Summary of Contents for ZM4

Page 1: ...2 3 4 5 6 7 8 9 10 ZONE 1 ZONE 2 ZONE 4 VOLUME MONITOR 0 1 2 3 4 5 6 7 8 9 10 VOLUME MONITOR 0 1 2 3 4 5 6 7 8 9 10 VOLUME MONITOR 0 1 2 3 4 5 6 7 8 9 10 0 10 PHONE PHONE VOLUME MONITOR VOLUME 0 10 MO...

Page 2: ...abels from the unit Do not open the equipment and do not modify the unit Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors...

Page 3: ...OLUME Z1 Z3 Z2 Z4 CH 3 0 1 2 3 4 5 6 7 8 9 10 10 10 10 10 10 10 VOLUME Z1 Z3 Z2 Z4 CH 4 0 1 2 3 4 5 6 7 8 9 10 10 10 10 10 10 10 VOLUME Z1 Z3 Z2 Z4 CH 5 0 1 2 3 4 5 6 7 8 9 10 10 10 10 10 10 10 ON OFF...

Page 4: ...10 10 10 10 10 10 VOLUME Z1 Z3 Z2 Z4 CH 2 0 1 2 3 4 5 6 7 8 9 10 10 10 10 10 10 10 VOLUME Z1 Z3 Z2 Z4 CH 3 0 1 2 3 4 5 6 7 8 9 10 10 10 10 10 10 10 VOLUME Z1 Z3 Z2 Z4 CH 4 0 1 2 3 4 5 6 7 8 9 10 10 1...

Page 5: ...he zone mixers input channels Turn the level control anti clockwise to the lowest setting or turn clockwise to adjust to the highest setting Adjustments should be made gradually to avoid any sudden ch...

Page 6: ...h On Off control for the zone amplifier Note The on off power switch does not have any control over the 24V DC power input 14 AC mains power input Before connecting the amplifier to the local mains vo...

Page 7: ...amplifier 22 Telephone paging input zone selection volume control The TEL input features zone control and input volume control To route the TEL signal to a desired output zone move the corresponding D...

Page 8: ...tion and all tone equaliser controls to the mid zero point Deselect all monitor and zone selection controls Switch on the zone mixer and any audio sources MP3 players CD players Microphones etc before...

Page 9: ...disconnected from any AC or DC power sources and disconnected from all inputs outputs Remove the 12 screws from the outer casing as per the diagram below and keep in a safe location Remove the upper...

Page 10: ...r PA Amplifier PA Amplifier Horn speaker Horn speaker Column speaker Column speaker Speaker Speaker Recorder CD Player AM FM Tuner 24V Recorder Desktop Mic Microphone Speaker Amplifier Contact Voice P...

Page 11: ...possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of materi...

Page 12: ...www cleveracoustics co uk ZM4 4 Zone Mixer User Manual 12...

Reviews: