Safety advice

WARNING

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL  
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Only use the equipment indoors.
•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available voltage is 240V, 50Hz.
•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically.

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again.

•  If the equipment has been exposed to drastic  

temperature fluctuation (e.g. after transportation),  
do not connect power or switch it on immediately.  
The arising condensation might damage the equipment. 
Leave the equipment switched off until it has reached 
room temperature.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Prolight 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  WARRANTY: Three years from date of purchase.

CAUTION!

KEEP THIS EQUIPMENT 

AWAY FROM RAIN,  

MOISTURE AND LIQUIDS

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

Summary of Contents for MA 135

Page 1: ...K DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN NO USER SERVICABLE PARTS INSIDE PRIORITY MA 135 Mixer Amplifier EQUALISER MIC 1 0 1 2 3 4 5 6 7 8 9 10 0 1...

Page 2: ...ormative labels from the unit Do not open the equipment and do not modify the unit Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipmen...

Page 3: ...veracoustics co uk SERIAL NUMBER COM 4 8 16 100V WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN NO USE...

Page 4: ...ISTURE CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN NO USER SERVICABLE PARTS INSIDE PRIORITY MA 135 Mixer Amplifier EQUALISER MIC 1 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 MIC 2 LINE 1 LINE 2 150H...

Page 5: ...components After connecting all audio sources and powering on the mixer amplifier adjust the level of each audio input to achieve the desired mix Care should be taken to when adjusting microphone inpu...

Page 6: ...s Music Mute The MA 135 amplifier features a priority feature for microphone 1 When the Priority contacts are shorted the amplifier will mute all other inputs while microphone 1 will remain active Lin...

Page 7: ...within the cable DO NOT connect a speaker load to the amplifiers output terminals of lower impedance than is marked on the output terminals 100V Line For longer cable runs the amplifier may be used to...

Page 8: ...EQUIPMENT TO RAIN OR MOISTURE CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN NO USER SERVICABLE PARTS INSIDE PRIORITY MA 135 Mixer Amplifier EQUALISER MIC 1 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10...

Page 9: ...1815 Q18 C 1815 Q14 D718 Q12 C 2240 Q13 A 1015 Q11 A 1015 Q9 C 2240 Q10 C 2240 R 82 22K R 81 7 5K R 83 7 5K R 87 1K R 86 7 5K R 84 4 7K R 67 1K R 85 12K R 68 33P R 63 680 R 78 270K R 79 10K R 64 22K R...

Page 10: ...ent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of mat...

Page 11: ...www cleveracoustics co uk MA 135 Mixer Amplifier User Manual 11...

Page 12: ...www cleveracoustics co uk MA 135 Mixer Amplifier User Manual 12...

Reviews: