Clever Acoustics CS 66F User Manual Download Page 3

www.cleveracoustics.co.uk

100V Ceiling Louds FD

  

User Manual

3

Product overview & technical specifications

Ceiling mounted loudspeakers ideal for the playback of music and speech 

reinforcement where audio quality is important. The CS F series utilise 

a coaxial design complete with HF tweeter for crystal clear high tones. 

The loudspeakers feature a full fire dome and ceramic connector block 

suitable for installations requiring fire resistant specification. During a fire, 

the ceiling cavity can allow fire or smoke to spread throughout a building. 

To inhibit fire entering the cavity via the ceiling loudspeaker a suitable 

product should chosen for installation.

• Coaxial, 2-way design delivers 

wide frequency response

• Multiple power taps (selected  

via internal jumper)

• Ceramic terminal block connection

• Metal grille, baffle and fire dome
• Spring clip mounting with “dome 

first” fast installation system

• Supplied with template to aid 

installation

100V 6W Ceiling S Fire Dome

Specifications

CS 56F

CF 66F

Input

100V, 70V

100V, 70V

Power taps @ 100V

0.38W, 0.75W, 1.5W, 3W, 6W

0.38W, 0.75W, 1.5W, 3W, 6W

Power taps @ 70V

0.19W, 0.38W, 0.75W, 1.5W, 3W

0.19W, 0.38W, 0.75W, 1.5W, 3W

Impedance

26KΩ, 13KΩ, 6.7KΩ, 3.3KΩ, 1.7KΩ

26KΩ, 13KΩ, 6.7KΩ, 3.3KΩ, 1.7KΩ 

Sensitivity (1W/1m)

92dB (±3dB)

92dB (±3dB)

Maximum SPL (Rated W/1m)

100dB

100dB

Frequency response

130Hz-15kHz

120Hz-18kHz

Drivers

5” LF, 1.5” HF

6” LF, 1.5” HF

Connections

Ceramic terminal block

Ceramic terminal block

Cutout

157mmØ

207mmØ

Dimensions

125 x 180mmØ

126 x 230mmØ

Weight

1.2kg

1.6kg

Order code

CRSP14

CRSP15

230mm (CS 66F)

180mm (CS 56F)

126mm (CS 66F)

125mm (CS 56F)

230mm

 (CS
 66F)

1

80mm

 (CS
 56F)

Summary of Contents for CS 66F

Page 1: ...Order codes CS 56F 100V 5 6W CRSP14 CS 66F 100V 6 6W CRSP15 Ceiling Loudspeakers Fire Dome User Manual...

Page 2: ...uit burns and electric shocks etc Incase of malfunction this device should be returned for service or inspection Do not endanger your own safety and the safety of others Incorrect installation or use...

Page 3: ...de frequency response Multiple power taps selected via internal jumper Ceramic terminal block connection Metal grille baffle and fire dome Spring clip mounting with dome first fast installation system...

Page 4: ...nual 4 Technical specifications 01 Loudspeaker grille 02 Loudspeaker housing fire dome 03 Loudspeaker housing locking plates 04 Loudspeaker 05 Power tap selector 06 Loudspeaker ceiling knock outs 06 0...

Page 5: ...he installation depends very much on the material used at the installation area building material such as wood concrete and brick etc This is why the fixing material must be chosen to suit the ceiling...

Page 6: ...www cleveracoustics co uk 100V Ceiling Loudspeaker FD User Manual 6 Mains CD Player AM FM Tuner 24V DC INPUT Optional Mic 1 Typical System Configurations...

Page 7: ...www cleveracoustics co uk 100V Ceiling Loudspeaker FD User Manual 7 Dispersion Characteristics CS 56F CS 66F...

Page 8: ...event possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of m...

Reviews: