Clever Acoustics CRAM33 User Manual Download Page 6

www.cleveracoustics.co.uk

MA 4120 480W Mixer Amplifier

  

User Manual

6

Operating instructions

10. LED VU output meter: 

The output to each zone may be monitored visually on the amplifier. The VU meter has three green 
stages, followed by amber and then red. Care should be taken to avoid the signal level reaching the 
amber or red zones as this will indicate a clipped signal within the zone mixer. In this instance, the Input 
Channel and/or Zone Output Level should be reduced.  

11. Monitor level control: 

The monitor output volume is adjustable. Turn the level control anti clockwise to the lowest setting, 
or turn clockwise to adjust to the highest setting. This is used to control the volume for the 1W 8Ω 
loudspeaker output on the rear panel of the zone mixer. 

12. Zone output level control: 

The master volume control affects all audio sources within the amplifier, routed to the selected zone. 
Turn the level control anti clockwise to the lowest setting, or turn clockwise to adjust the overall output 
to the highest setting. Adjustments should be made gradually to avoid any sudden changes to the audio 
output.

13. Monitor output selector: 

To route one of the output zones to the monitor & headphone outputs, press the Monitor selection 
button. The monitor output volume can then be adjusted using the Monitor Volume Control.

14. Power LED: 

The Power LED will illuminate to indicate the zone mixer is powered on. If the power LED is not 
illuminated, check first the position of the on/off switch and then check the mains (including fuse) or DC 
power supply.

15. Power switch: 

On/Off control for the zone amplifier. Note: The on/off power switch does not have any control over the 
24V DC power input.

16. Cooling fan: 

The MA 4120 MKII is fan cooled. The cooling fan will start when the internal temperature sensor 
reaches 50°C. The fan speed will vary according to the internal temperature of the amplifier. Do not 
block or obstruct the fan port on the rear panel or the air vents on the top or side panels.  

17. AC mains power input: 

Before connecting the amplifier to the local mains voltage outlet should be checked to ensure the 
available supply is 240V~AC 50Hz. This product is CLASS1 and requires a protective mains earth to be 
connected at all times. DO NOT remove or disconnect the earth. 

18. AC mains fuse: 

Disconnect from the mains power supply before attempting to replace the mains fuse. Replacement 
mains fuses must be the same rating as the original. T6.3AL 250V for 220-240V AC mains supply or 
T12AL 250V for 110-120V AC mains supply.

 
 
 

Summary of Contents for CRAM33

Page 1: ...9 10 VOLUME MONITOR 0 1 2 3 4 5 6 7 8 9 10 ON OFF POWER 0 1 2 3 4 5 6 7 8 9 10 CH4 CH2 CH1 CH3 L R CH5 LINE POWER INPUT 110 240V 50 60Hz 110 120V 60Hz FUSE T12A 250V 220 240V 50 60Hz FUSE T6 3A 250V...

Page 2: ...ative labels from the unit Do not open the equipment and do not modify the unit Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment i...

Page 3: ...Z1 VOL BASS MUTE TREBLE GAIN Z3 Z2 Z4 CH 3 0 1 2 3 4 5 6 7 8 9 10 10 10 10 10 10 10 Z1 VOL BASS MUTE TREBLE GAIN Z3 Z2 Z4 CH 4 0 1 2 3 4 5 6 7 8 9 10 10 10 10 10 10 10 Z1 VOL BASS MUTE TREBLE GAIN Z3...

Page 4: ...PARTS INSIDE MONITOR LINE OUTPUT G MONITOR 1W 8 PRIORITY TEL PAGING COM GND HOT 110 120V 220 240V PHANTOM LINE MIC PHANTOM LINE MIC PHANTOM LINE MIC PHANTOM LINE MIC TEL VOLUME ZONE LINE OUT BAL UNBA...

Page 5: ...output 4 Mute switch Press the mute switch to mute silence the selected input channel 5 Mute LED The mute LED provides a visual indication when the input channel is in mute status 6 Input channel leve...

Page 6: ...ones to the monitor headphone outputs press the Monitor selection button The monitor output volume can then be adjusted using the Monitor Volume Control 14 Power LED The Power LED will illuminate to i...

Page 7: ...Mute function 23 Telephone paging input TEL For emergency paging the MA 4120 MKII is equipped with a balanced audio TEL input activated automatically upon the MA 4120 MKII detecting an audio signal p...

Page 8: ...V 100V Do not use more than one pair of output terminals on any one output zone Care should be taken when connecting to the outputs to ensure the load impedance is above the minimum load specified for...

Page 9: ...st be fully disconnected from any AC or DC power sources and disconnected from all inputs outputs Remove the 15 screws from the outer casing as per the diagram below and keep in a safe location Remove...

Page 10: ...20 480W Mixer Amplifier User Manual 10 Typical panel connections Mains Recorder PA Amplifier Recorder CD Player AM FM Tuner Desktop Mic Microphone Monitor Speaker Amplifier Contact Voice Priority Horn...

Page 11: ...will mostly be absorbed if the cables are unnecessarily long Besides that a longer cable may lead to humming and noise problems If the cable runs are unavoidable you should use balanced cables Outputs...

Page 12: ...revent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of...

Reviews: