Installation Requirements, Cont'd
Feedwater chemistry:
Parameter
Feed TDS
Up to 2000 ppm
Feed pH
5-11
Hardness
20 grains or less
Free chlorine
<2mg/l
Iron (Fe)
. 1 mg/I maximum
Manganese
.05 mg/1 maximum
Hydrogen sulfide
none allowable
Turbidity
<5NTU
If your water analysis indicates that any of these parameters are not in range, additional pretreatment or higher frequency
of maintenance may be required. Contact your SteamerGard distributor or the factory for assistance. NOTE: The presence
of silica or flocculants (e.g. alum or cationic polymers) in the feedwater can cause membrane fouling and may require
special chemical pretreatment or periodic membrane cleaning.
Electrical requirements:
Model
WT-300, WT-600
WT-900
Electrical
115 VAC, 60 Hz, 6.2 Amp.
115 VAC, 60 Hz, 7.5 Amp.
Motor
1/3 HP
1/2 HP
Pump
Rotary vane type
Rotary vane type
Drain
Drain must allow a minimum flow of 5 gallons per minute.
Follow local plumbing codes for connection of drain line. Most plumbing codes require the installation of an
approved air gap in the drain line.