Cleveland SteamChef 22CET3.1 Operator'S Manual Download Page 29

23

BURN, SCALD AND EQUIPMENT DAMAGE HAZARD 

If the drain is blocked, hot water can fill the cooking compartment and spill out when the 
cooking compartment door is opened. 
Signs of blocked drains include steam or water leaks around the cooking compartment door, 
and reduced cooking performance. 
To help avoid injury: 

 

Stand on the hinge side and away from the appliance and slowly open the cooking 
compartment door. 

 

Inspect the drain(s) before each use and clean them if needed. 

Failure to follow these precautions can cause burns, scalds, and equipment damage.

TROUBLESHOOTING NOTES 

1.  If the problem is inside the appliance, call a qualified Cleveland Range authorized service 

representative or Cleveland Range. (Please have the model number and serial number ready when 
calling.) Cleveland Range will not pay for warranty repairs by unauthorized maintenance and repair 
centers. 

2.  Proper installation of the appliance is the responsibility of the Owner-User. Refer to the Warranty. 

3.  Repairs to external plumbing must be done by a Licensed Plumber.  

4.  Repairs to external wiring must be done by a Licensed Electrician.  

5.  If the automatic fill system fails for any reason, the steamer will stop heating when the water level 

drops below the minimum operating level. The steamer can be operated by manually filling the water 
reservoir with about a gallon of water approximately every half-hour, until service can be performed. 

6.  For more information on products and services, contact your nearest Authorized Sales 

Representative. Call the factory for a preventative maintenance program, descaling information, and 
water treatment systems. 

7.  Whenever opening door, especially when water or steam is leaking around the gasket, heed the 

warning below. 

8.  Use the Egg Test to evaluate steamer performance. 

 

NOTE: this test is not valid for pressure steamers. 

1)  Turn on the steamer, and set the selector switch to the manual mode (or for ON/OFF models 

set the selector to the ON position) so that steam is produced. 

2)  Preheat the steamer for ten minutes. 

3)  After the compartment is preheated, place a fresh egg on a perforated steam table pan in the 

middle of the cavity. 

4)  Close the door and set the timer as directed by the size chart below 

Egg Size 

Time 

Medium 

12 minutes 

Large 

14 minutes 

Extra Large 

14 minutes 

5)  Carefully remove the egg and place in a container with cold water running over it. 

6)  Let cool under cold running water for 5 minutes.

7)

  After cooling, crack eggshell and peel.

8)  A properly operating steamer produces a perfect hard-boiled egg. 

9.  Although, a SteamChef Steamer normally should not require descaling, the use of extremely “hard” 

water or failure to follow the cleaning procedures in the Shutdown and Cleaning Instructions may 
cause scale buildup. Have Cleveland Range authorized technicians or trained onsite maintenance 
personnel descale the steamer. 

Summary of Contents for SteamChef 22CET3.1

Page 1: ...OPM REV C 5 07 Operator s Manual Energy Star SteamChef Models 22CET3 1 and 22CET6 1 1333 East 179th Street Cleveland Ohio 44110 Phone 216 481 4900 1 800 338 2204 Fax 216 481 3782 www clevelandrange co...

Page 2: ...ehold use FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance Improper installation adjustment alteration service or mainte...

Page 3: ...r see Water Quality Recommendations below THE USE OF POOR QUALITY FEED WATER WILL VOID EQUIPMENT WARRANTIES Boiler maintenance supplies including boiler hand hole gaskets are not warranted beyond the...

Page 4: ...Procedures Review of Maintenance Procedures Start of Warranty Protection Equipment Demonstration After your Performance Check Out contact your Cleveland Range sales representative for your free Equip...

Page 5: ...stall Remove the Slide Racks Pan Racks 6 E Install Remove the KleanShield 6 F Install the Fan Guard and Air Diverter 7 G Power ON Auto Water Fill Automatic Preheat 8 H Preheat the Steamer 8 I High Lim...

Page 6: ...6 Shutdown and Cleaning 15 A Shutdown and Cleaning Procedure 15 7 Preventative Maintenance 17 A Maintenance 17 B Descale the Water Reservoir 18 8 Operator s Troubleshooting Guide 21...

Page 7: ...and procedures outlined in this manual 5 Installation must comply with all local fire and health codes B Operational Safety The Operational Safety section outlines minimum safety policies and procedu...

Page 8: ...nd on the hinge side and away from the appliance and slowly open the cooking compartment door Open the door slightly to allow steam condensate and heat to vent before looking or reaching into the cook...

Page 9: ...erial Numbers 1 Cleveland Range LLC assigns two product identification numbers to each appliance a model number and a serial number 2 Please provide this information when you contact Cleveland Range o...

Page 10: ...Views Drain Valve Power ON OFF Lever Figure 2 1 SteamChef Steam Cooker Front View Model 22CET3 1 Shown Model Serial Number Insert Product Information Plate Water Fill Connection Drain Outlet 4 Adjusta...

Page 11: ...Remove the door gasket assembly pan racks backplate fan guard and KleanShield and make sure all surfaces are clean and drain openings and the water level sensors are clean and free of any residue or...

Page 12: ...top and bottom pins 4 Repeat steps 1 2 and 3 for the other rack E Install Remove the KleanShield Note The KleanShield is dishwasher safe To Install the KleanShield 1 Remove the pan racks 2 Place the K...

Page 13: ...See Figure 3 6 1 Hold the fan guard so that the large ends of the keyholes are towards the bottom of the steamer 2 Place all four openings over the mounts located on the rear wall of the steamer 3 Pu...

Page 14: ...roductivity and consistency BEFORE PREHEATING Inspect and clean the compartment After preheating the compartment will be too hot to inspect and clean safely To preheat the SteamChef Steamer 1 Close th...

Page 15: ...ESET Indicator lights when the High Limit circuit trips The light stays ON and a buzzer sounds until the appliance is reset To reset 1 Turn OFF power to the steamer with the Power ON OFF Lever 2 Wait...

Page 16: ...WER ON Indicator Light When the Green indicator light is ON power is ON to the controls 4 RESET Indicator lights when the High Limit circuit is open The light stays ON and a buzzer sounds until the ap...

Page 17: ...ts when the High Limit circuit is open The light stays ON and a buzzer sounds until the appliance is reset To reset Turn OFF power to the steamer with the Main Power ON OFF LEVER Wait 15 minutes for t...

Page 18: ...door is stuck shut Turn OFF the steamer Call a qualified Cleveland Range authorized service technician Wait for the steamer to cool before servicing Hot Air Steam and Condensate will cause Burns and...

Page 19: ...time f Close the cooking compartment door 2 While cooking occasionally check the water in the reservoir for food particles and oils If the water is dirty or cloudy change the water See Chapters 3 and...

Page 20: ...in the Manual Mode with a fixed 60 minute timer For longer cooking times switch OFF and back ON to reset the fixed 60 minute timer When turned OFF the cooking compartment lowers to Standby temperatur...

Page 21: ...cedure should be performed at the end of each day or shift or more frequently if the water supply does not meet the Minimum Water Quality Requirements in the Warranty The steamer stays hot for a long...

Page 22: ...use of detergent but if detergent has been used to clean the inside of the steamer be sure to rinse off the probe assembly with the vinegar solution If detergent residue is not completely rinsed from...

Page 23: ...aminated with food particles CHANGE THE WATER IN THE STEAMCHEF STEAMER AT LEAST EVERY DAY IN ORDER TO MAINTAIN FOOD QUALITY AND KEEP THE STEAMER SANITARY Note It may be necessary to change the water s...

Page 24: ...leveland Range authorized technicians or trained onsite maintenance personnel may perform this procedure 1 Is Descaling Necessary a Although a SteamChef should not normally require this procedure the...

Page 25: ...atment and spill control DANGER The liquid solution in Cleveland Range Descaler Solution Part No 106174 can be harmful if not handled properly Follow these basic safety rules for handling and using th...

Page 26: ...eservoir is filling with water pour 1 to 1 quarts about a third of a 1 gallon bottle of DISSOLVE descaler solution into the water reservoir While adding DISSOLVE descaler to the reservoir pour it in s...

Page 27: ...iance does not fill with water Inoperative controls or solenoids See Notes 1 and 5 High limit has been tripped Reset steamer If problem repeats see Note1 Control panel Power indicator is on buzzer sou...

Page 28: ...mount of steam may issue from the exhaust whenever the unit is in the cooking mode This is normal operation of the steamer NO action is necessary Condenser water supply is turned OFF Turn ON Condenser...

Page 29: ...th about a gallon of water approximately every half hour until service can be performed 6 For more information on products and services contact your nearest Authorized Sales Representative Call the fa...