Cleveland PGDM1000 Operator'S Manual Download Page 2

 

 

 

 

 

 

For AMC180 & 400 Rate controllers see other manuals on our website

 

For WGF Shrouded booms see other manuals on our website

 

 

Disclaimer:

 

Cleveland Alliances Ltd accept no liability for damage caused to the machine or the environment or per-

sons through operation or misuse of the machine.  The operator must be competent, trained, and have the 

appropriate certification. 

 

DO NOT USE THIS MACHINE UNLESS YOU HAVE BEEN TRAINED TO DO SO.

 

 

 

For technical support and spare parts assistance call 01361883418

 

Email us on [email protected]

 

 

Cleveland Alliances Ltd

 

Station Road, Duns, Berwickshire, TD113HS

 

Summary of Contents for PGDM1000

Page 1: ......

Page 2: ...o the machine or the environment or per sons through operation or misuse of the machine The operator must be competent trained and have the appropriate certification DO NOT USE THIS MACHINE UNLESS YOU HAVE BEEN TRAINED TO DO SO For technical support and spare parts assistance call 01361883418 Email us on info clevelandalliances com Cleveland Alliances Ltd Station Road Duns Berwickshire TD113HS ...

Page 3: ...his her personal safety at work Refer to the danger indications on the labels of the products used Always work in the correct weather conditions and follow the weather forecasts for the en tire period of application Dose the product to be poured into the tank correctly Make sure that the chemical substances used are compatible with the construction materials of the machine Never leave chemical sub...

Page 4: ...ins and then connect the centre front pin to the tipping ram Make sure all lynch pins R pins are in place 2 When the machine is connected to the truck check the area is clear and lift the Sprayer using the tipping ram The connect the hydraulic pump hoses to the hydraulic service on the truck The engine should NOT be running when doing this 3 Connect the electrical cables to the control boxes NEVER...

Page 5: ...r you 4 Add the rest of the water to the required level Controls Operation Boom Section Valves The sections are controlled from the cab switch box Pressure Balancing To set the pressure balancing valves follow this procedure 1 Set the total boom spraying 3bar pressure 2 Turn off section 1 if the pressure increases above 3 bar turn the balancing valve anti clockwise until the pres sure is at 3 bar ...

Page 6: ... not get your dealer to install one Push in cigarette lighter type sockets are not good enough for professional 12v connections Electric controls supplied as either 3 section or 5 section Boom section switches Operation Spray On Spray Off Whole boom Pressure Increase Pressure Decrease Foam Marker Left Boom Right Boom ...

Page 7: ...g RIGHT Clean Water Suction Valve Arrow pointing LEFT Main Tank Suction SUCTION FILTER LOCATED UNDER THE PUMP To clean the suction filter WEEKLY you must re move the yellow plunger first Once it is removed you should unscrew the large filter nut and remove the filter element to clean Be careful not to lose the large filter O ring in the housing Once cleaned put back together and make sure the fil ...

Page 8: ...lve is at 3 oclock or 9 oclock posi tion the hopper will not empty To empty turn the valve to the 12 oclock or 6 oclock posi tion The pump need to be running at a minimum of 400rpm PTO speed Arrow on the valve handle pointing towards the centre of the hopper left means the hopper is on and ready to use Arrow on the valve handle pointing towards the boom right means the hopper is off and you are re...

Page 9: ...d boom arm towards you and open it towards the right hand side of the machine Be sure to locate the boom in the fully open position Once the right hand boom arm is secured pull the left hand boom arm towards you and open it towards the left hand side of the machine Be sure to locate the boom in the fully open position On a weekly basis APPLY GREASE to the folding mechanism when the boom arm is hal...

Page 10: ... rigidity and cause the boom to bend in there is collision Usually 20 to 25mm of thread above the adjustment nut is adequate To open the boom You will have 2 switches mounted on a box which has a 12v feed near the drivers position You can open either boom at any time or both booms together There is a fuse for each switch un derneath the switch on the external area of the switch box On a weekly bas...

Page 11: ...Nozzle Application Chart ...