NT-100 Peristaltic Pump Filler 

Operation Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for NT-100

Page 1: ...866 888 6327 sales clevelandequipment com 3889 E Raines Rd Memphis TN 38118 www clevelandequipment com NT 100 Peristaltic Pump Filler Operation Manual...

Page 2: ...NT 100 Peristaltic Pump Filler Page 2...

Page 3: ...Product Description 6 2 1 Components 6 2 2 Control Interface 7 2 3 Control Panel 8 2 4 Parameter Setting 9 2 5 Technical Specification 10 3 Before Operation 11 3 1 Connections 11 3 2 Driven Pump And...

Page 4: ...NT 100 Peristaltic Pump Filler Page 4...

Page 5: ...warning may expose the operator to danger Do not place the machine near high temperature or inflammables The places where are not stable or where the machine will be crashed easily are also not suita...

Page 6: ...NT 100 Peristaltic Pump Filler Page 6 2 Product Description 2 1 Components liquid outlet side liquid inlet side...

Page 7: ...itch Socket for Power Supply Cable 2 Knob for filling speed adjustment Clockwise speed up Counterclockwise slow down 3 Emergency Stop Button 4 Knob for Filling Mode Left Test mode Middle Manual mode R...

Page 8: ...g the parameters you want to set Parameter entering setting the parameters you need to push SET button for entering 3 SHIFT This button is for shifting the location of the blinking cursor for adjustin...

Page 9: ...ume 2P Delay time for Auto Mode In Auto Mode whenever the machine finishes filling one bottle it will fill the next one 2 seconds later automatically as the setting shows 02 0 in the picture on the ri...

Page 10: ...c Pump Filler Page 10 2 5 Technical Specification Model FG 100 Filling Range 10 5000 ml Filling Accuracy 1 Power Supply 110 or 220 VAC 50 60 Hz Single phase Driven Device DC Motor Dimension L 475 mm W...

Page 11: ...NT 100 Peristaltic Pump Filler Page 11 3 Before Operation 3 1 Connections Step1 Open the pump Step2 Open the gripper...

Page 12: ...NT 100 Peristaltic Pump Filler Page 12 Step3 Insert the tube into the slot Step4 Close the pump...

Page 13: ...push the start button continuously until there is no more air in the filling hosess and then assemble the filling nozzle back to the opening of the outlet hose immediately 3 2 5 Fix the filling nozzle...

Page 14: ...ergency stop button as shown on P 3 clockwise to activate the function 4 1 3 Place the bottle or container which you want to fill under the filling nozzle and adjust the machine with proper filling sp...

Page 15: ...ed filling volume and then note down the parameter shown on the screen Please push continuously or the parameter will not be accurate for the filling volume 4 1 5 Switch to Manual Mode and get into th...

Page 16: ...4 1 6 After setting the screen will show the value 0 again and the filler is ready for operating 4 1 7 While filling the screen will show the number of the bottles or containers being filled to assist...

Page 17: ...rature will cause resistance overloading of the control components and then affect the life span of the machine 5 2 3 After filling please be sure to clean the hoses and the pump to keep the machine c...

Page 18: ...he setting and filling processes 3 Check if using a foot pedal or any manual operation assisting devices Once using those devices the filler will adopt the signal from them in priority Bubbles Appear...