Supply Phase Wires HZ Supply Wire
Voltage
Amps
Size
200-208
3
3
60
15
12
220-240
3
3
60
14
12
380-415
3
3
60
9
14
440-480
3
3
60
7
14
SECT.
XI
PAGE
14
0707
Litho in USA
(NOT TO SCALE)
NOTES
:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Installation of backflow preventers, vacuum breakers and other specific coder requirements is the responsibility of the owner and installer.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others.
40/150
60/225
80/300
100/375
125/475
150/575
200/750
250/938
98.00
2489
105.00
2667
112.00
2845
121.00
3073
130.00
3302
130.00
3302
144.00
3658
150.00
3810
58.00
1473
26.00
660
61.50
1562
65.00
1651
69.50
1756
74.00
1880
74.00
1800
82.00
2083
85.00
2159
29.50
749
33.00
838
35.50
902
40.00
1016
40.00
1016
45.00
1143
48.00
1219
40.50
1029
40.50
1029
42.50
1080
44.50
1130
44.50
1130
48.50
1232
52.00
1321
56.00
1422
50.00
1270
50.00
1270
52.00
1321
54.00
1372
54.00
1372
58.00
1473
61.50
1562
65.50
1664
69.25
1759
70.25
1784
74.75
1899
78.25
1988
83.00
2108
87.00
2210
94.50
2400
100.00
2540
7.50
191
7.50
191
9.50
241
11.50
292
11.50
292
15.50
394
17.50
445
21.50
546
37.75
959
41.25
1048
44.75
1137
48.25
1226
52.75
1340
52.75
1340
58.75
1492
61.75
1568
30.00
762
31.00
787
32.00
813
33.00
838
34.00
864
34.00
864
41.00
1041
42.00
1067
12.00
305
8.50
216
8.50
216
8.50
216
8.00
203
7.25
184
8.50
216
9.00
229
15.25
387
10.75
273
10.25
260
10.13
257
8.625
219
9.00
229
11.50
292
12.00
305
36.38
924
39.13
994
39.88
1013
41.13
1045
40.375
1026
44.00
1118
46.75
1187
48.75
1238
23.13
587
23.13
587
23.13
587
23.13
587
23.13
587
23.13
587
27.75
705
27.75
705
27.375
695
27.375
695
27.375
695
29.375
746
29.375
746
29.375
746
34.00
864
34.00
864
36.00
914
36.00
914
36.00
914
36.00
914
36.00
914
36.00
914
43.00
1092
43.00
1092
18.375
467
18.375
467
18.375
467
18.375
467
18.375
467
18.375
467
23.00
584
23.00
584
28.00
711
28.00
711
28.00
711
28.00
711
28.00
711
28.00
711
35.00
889
35.00
889
10.00
254
10.00
254
10.00
254
12.00
305
12.00
305
12.00
305
12.00
305
12.00
305
18.00
457
18.00
457
18.00
457
18.00
457
18.00
457
18.00
457
20.00
508
20.00
508
26.50
673
26.50
673
26.50
673
26.50
673
26.50
673
26.50
673
28.00
711
28.00
711
7.75
197
7.75
197
7.75
197
7.75
197
7.75
197
7.75
197
8.25
210
8.25
210
5.25
133
5.25
133
5.25
133
5.25
133
5.25
133
5.25
133
5.75
146
5.75
146
6.50
165
6.50
165
6.50
165
6.50
165
6.50
165
6.50
165
7.50
191
7.50
191
5.75
146
5.75
146
5.75
146
5.75
146
5.75
146
5.75
146
6.75
171
6.75
171
1.75
44
1.75
44
1.75
44
2.50
64
2.50
64
2.50
64
2.50
64
2.50
64
12.50
318
12.50
318
12.50
318
12.50
318
12.50
318
12.50
318
14.50
368
14.50
368
12.50
318
12.75
324
13.50
343
15.75
400
16.50
419
16.50
419
17.50
445
18.00
457
60.50
1537
64.25
1632
68.50
1740
73.25
1861
81.50
2070
81.50
2070
87.50
2223
91.00
2311
25.00
635
28.00
711
30.00
762
32.00
813
35.00
889
35.00
889
39.00
991
41.00
1041
6.50
165
8.00
203
9.00
229
10.00
254
11.50
292
11.50
292
13.50
343
14.50
368
13.625
346
14.88
378
16.13
410
17.00
432
18.50
470
18.50
470
20.375
518
21.50
546
na
na
na
3.25
83
3.25
83
3.25
83
3.25
83
3.25
83
39.00
991
GAL/LIT.
A
B
C
D
E
F
G
H
J
K
L
M
N
0
P
Q
R
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
EE
FF
GG
HH
40.75
1035
42.75
1086
43.75
1111
46.00
1168
46.00
1168
53.75
1365
55.375
1407
5.375
137
LL
5.375
137
5.375
137
5.375
137
5.375
137
5.375
137
6.375
162
6.375
162
74.25
1886
MM
75.25
1911
79.75
2026
83.25
2115
88.00
2235
92.00
2337
DIMENSIONS
("/mm)
S
B
T
D
H
C
3.00"
76mm
6.50"
166mm
G
K
U
D
E
C
(I.D.)
8.44"
214mm
ZZ
N
O
HH
L
F
MM
SEE
RECOMMENDED
FLOOR SLOPE
KETTLE LIP IN
TILTED POSITION
M
18"
(457mm)
RECOMMENDED
21.00"
533mm
SEE SOLID
FOOT DETAIL
FLOOR
DRAIN
GRATE
Q
R
FF
5"
127mm
5.00"
127mm
DD
BB
6.00"
152mm
J1
(DRAIN
GRATE)
J2
(DRAIN
GRATE)
HAA
Q
5"
127mm
12"
305mm
EE
(TYP.)
FLOOR SLOPE = 1.00" (26mm) per 4' (1220mm)
RECOMMENDED FLOOR SLOPE
PIPE DRAIN RECOMMENDED
min. valve size plus 1.00" (26mm)
6.00" (153mm) RECOMMENDED
4.00" (102mm) MINIMUM
CONSOLE FOR
40 - 80 GAL. MODELS
(TYP.)
CONSOLE FOR
100 - 250 GAL. MODELS
(TYP.)
G
G
G
G
SEE
DETAIL A
DETAIL A
6.5"
165mm
5.75"
148mm
LL
T
7.25"
184mm
W
V
H
C
D
1.75"
44mm
3.00"
76mm
SOLID FOOT DETAIL
5 1/2" (140 mm)
3/8"
(10 mm)
2"
(51 mm)
1" (26 mm)
MAX. ADJUSTMENT
5/8" Ø
(16 mm)
2 HOLES
ON 4"
(102 mm)
B.C.D.
4
0
-1
5
0
G
A
L
.
ELECTRICAL
UTILITIES
STEAM JACKET RATING
4" NPT
C
NPT
" NPT
A
NPT
H
Direct Steam - 3/4" NPT (40 - 80 Gal.),
1 1/4" NPT (100 - 150 Gal.)
Condensate Return - 3/4" NPT
Hot Water Faucet - 3/4" NPT
C
D
Cold Water Faucet - 3/4" NPT
Cooling Water In - 3/4" NPT
Cooling Water Out - 3/4" NPT
Automatic Drain - 3/8" NPT
PSI
35
50
70
40 Gal.
N/A ST OP
60 Gal.
N/A ST OP
80 Gal.
N/A ST OP
PSI
35
50
70
100 Gal.
N/A ST OP
125 Gal.
ST N/A OP
150 Gal.
ST N/A OP
ST - Standard, OP - Optional, N/A - Not Available
Right
- 0,
Left
- 0
Rear
-
18" (457mm) Recommended
0 - Minimum
CLEARANCE