NOTES
:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers.
SECT.
IIA
PAGE
26
0108
The "Advanced Closed System" offers the following advantages:
II
Saves energy
II
Automatic moisture level adjustment
II
Low heat and steam emission to the kitchen
II
Automatically regulated steam injection
II
Enables immediate change into the steam mode
II
"Crisp & Tasty" demoisturizing function
Model:
OGB-12.20
Pan Capacity
[Unit (trolley) has 12 slide rails at 2.64" (67mm) apart]
:
12
(20" x 26") full size wire racks
12
(18" x 26") full size sheet pans -
on wire racks
24
(13" x 18") half size sheet pans -
on wire racks
24
(12" x 20" x 2 1/2") steam table pans
24
(12" x 20" x 1") steam table pans
24
(12" x 20") frying baskets - (
no wire racks needed
)
For Banquet Operations:
Optional Plate Rack holds 74 plates
Unit Dimensions:
Width - 53.83", Depth - 44.34", Height - 57.73"
Shipping Dimensions:
Width - 60", Depth - 50", Height - 66"
(including packaging)
Shipping Weight:
717 Lbs (including trolley)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located
next to the unit.
• Allow for sufficient clearance on left side for service access (contact the
factory service department for recommendations).
• Installation must comply with all local fire and health codes.
Agency Approvals:
UL - Gas, UL - Sanitation (NSF Standards)
Electrical Requirements:
120 volt, 15.9 amps, 60 Hz, single phase
Do not connect to a G.F.I. outlet
Gas Connection:
3/4" NPT
Gas Type:
Natural Gas (Propane optional)
Gas Flow Pressure:
Natural Gas - Min. 5.5" WC / Max. 14" WC
Propane Gas - Min. 11" WC / Max. 14" WC
Total Connected Load:
151,500 BTU (136,000 BTU Propane)
Steam Generator:
132,700 BTU (119,000 BTU Propane)
Hot Air:
151,500 BTU (136,000 BTU Propane)
Water Connections:
Cold Water (drinking water quality)
Flow Pressure:
30 - 60 PSI
Water Inlets:
3/4" GHT-F (Female Garden Hose Connection)
Treated Water for Steam Generator
Untreated Water for Condenser and Hand Shower
Drain Connection:
2" Tube
Venting:
Exhaust Hood required
Gas Exhaust for Hot Air Heating
Gas Exhaust for Steam Generator
Air Vent
*Connection for Cleaning Solution
*Connection for Rinse Cycle
Low Pressure Safety Valve
*
Available as an option
48.51"
2.52"
1.58"
4
6
.7
0
"
9.06"
2.80"
5
6
.1
5
"
4
1
.5
4
"
2
.8
0
"
12.68"
2.80"
8.55"
2
.6
0
"
3
.3
9
"
4
.8
1
"
7
.4
8
"
1
3
.0
8
"
3.08"
1
4
.2
6
"
10.87"
42.29"
3.15"
6.50"
1
0
.4
0
"
2
5
.7
9
"
1
8
.9
0
"
2
.9
6
"
2
7
.2
9
"
1
.1
9
"
29.57"
5.48"
3.00"
4.97"
S
AV
E1
E2
RC
CS
W1
W2
D
G
FRONT VIEW
TOP VIEW
BOTTOM VIEW
31.50"
48.51"
2.52"
1.58"
4
6
.7
0
"
9.06"
2.80"
5
6
.1
5
"
4
1
.5
4
"
2
.8
0
"
12.68"
2.80"
8.55"
3
.3
9
"
4
.8
1
"
7
.4
8
"
1
3
.0
8
"
3.08"
1
4
.2
6
"
10.87"
42.29"
3.15"
6.50"
1
0
.4
0
"
2
5
.7
9
"
1
8
.9
0
"
2
.9
6
"
2
7
.2
9
"
1
.1
9
"
29.57"
5.48"
3.00"
4.97"
S
AV
E1
RC
CS
W1
W2
D
G
FRONT VIEW
TOP VIEW
BOTTOM VIEW
31.50"
48.51"
2.52"
1.58"
4
6
.7
0
"
9.06"
2.80"
5
6
.1
5
"
4
1
.5
4
"
2
.8
0
"
12.68"
2.80"
3
.3
9
"
1
3
.0
8
"
3.08"
1
4
.2
6
"
10.87"
42.29"
3.15"
6.50"
2
5
.7
9
"
1
8
.9
0
"
2
.9
6
"
2
7
.2
9
"
1
.1
9
"
29.57"
5.48"
3.00"
4.97"
S
AV
RC
CS
W1
W2
D
FRONT VIEW
TOP VIEW
BOTTOM VIEW
31.50"
A = Water hook up soft water G"
B = Water hook up cold water G"
C = drainage hook up DN50
D = power hook up
E = Potential equaliser
F = Final rinse hook up
G = Cleaner hook up
H = Air vent pipe
I = Low pressure safety
OEB 12.20
A = Water hook up soft water G"
B = Water hook up cold water G"
C = drainage hook up DN50
D = power hook up
E = Potential equaliser
F = Final rinse hook up
G = Cleaner hook up
H = Air vent pipe
I = Low pressure safety
OES 12.20
OGB 12.20
A Water hook up soft water G"
B Water hook up cold water G"
C Drainage hook up DN50
D Power hook up
E Potential equaliser
F Final rinse hook up
G Cleaner hook up
H Air vent piper
I Low pressure safety
J Gas hook up R"
K Exhaust pipe gas (Hot air heating)
L Exhaust pipe gas (Steam generator)
OGS 12.20
A = Water hook up soft water G"
B = Water hook up cold water G"
C = Drainage hook up DN50
D = Power hook up
E = Potential equaliser
F = Final rinse hook up
G = Cleaner hook up
H = Air vent pipe
I = Low pressure safety
J = Gas hook up R"
K = Exhaust pipe gas
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2