Cleveland ConvectionPro XVI 36-CEM-16-48 Specification Sheet Download Page 2

(NOT TO SCALE)

SECT.

III

PAGE 

26

0707

Litho in U.S.A

Each compartment has capacity for:
Eight, 12˝ x 20˝ x 2

1

2

˝ deep Cafeteria Pans. Can 

accomodate 18˝ x 26˝ Bun Pans.

Many regional, state and local codes exist and it is the
responsibility of the owner and installer to comply with
those codes.

Cleveland Range equipment is built to comply with
applicable standards for manufacturers. Included
among those approval agencies are: UL, A.G.A.,
NSF, ASME/N.Bd., CSA, CGA, ETL, and others.

WATER QUALITY REQUIREMENT

The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours of
use per day, and a Daily Blowdown, are as follows:

TOTAL DISSOLVED SOLIDS

less than 60 parts per million

TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam

generator feed water treatment (if required), in order to

remove or reduce harmful concentrations of minerals. The
use of highly mineralized water will mean that more frequent
servicing of the steam generator will be necessary. The fact
that a water supply is potable is not proof that it will be 
suitable for the generator.

NOTES

:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA.

KW

Volts

Watts

Ph

Amps

Wire

48

208

42,900

3

119.2

3

220

48,000

3

126.1

3

240

48,000

3

115.6

3

440

40,300

3

52.9

3

480

48,000

3

57.8

3

600

48,000

3

46.2

3

360

42,900

3

68.9

4

380

48,000

3

73.0

4

415

48,000

3

66.9

4

ELECTRIC

WATER

DRAINAGE

CLEARANCE

C

D

The Floor Drain must be located
outside the confines of the 
equipment base.

1 1/2˝ I.P.S.  common drain.

Do not connect other units to this drain.
Do not use PVC pipe for drain.

Cold Water Inlet
35 psi minimum
60 psi maximum

1/4˝ NPT
Condenser feed
3/8˝ NPT Boiler
feed

Right - 3”, Left - 3”, 
Rear - 3”  (12” on control
side if adjoining wall or
equipment is over 30” high
for service access)

Contact factory for 
variances to clearances.

Reviews: