Each compartment has capacity for:
Eight, 12˝ x 20˝ x 2
1
⁄
2
˝ deep Cafeteria Pans. Can
accomodate 18˝ x 26˝ Bun Pans.
•
Many regional, state and local codes exist and it is the
responsibility of the owner and installer to comply with
those codes.
•
Cleveland Range equipment is built to comply with
applicable standards for manufacturers. Included
among those approval agencies are: UL, A.G.A.,
NSF, ASME/N.Bd., CSA, CGA, ETL, and others.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours of
use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS
less than 60 parts per million
TOTAL ALKALINITY
less than 20 parts per million
SILICA
less than 13 parts per million
pH FACTOR
greater than 7.5
CHLORINE
less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals. The
use of highly mineralized water will mean that more frequent
servicing of the steam generator will be necessary. The fact
that a water supply is potable is not proof that it will be
suitable for the generator.
NOTES
:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA.
KW
Volts
Watts
Ph
Amps
Wire
48
208
42,900
3
119.2
3
220
48,000
3
126.1
3
240
48,000
3
115.6
3
440
40,300
3
52.9
3
480
48,000
3
57.8
3
600
48,000
3
46.2
3
360
42,900
3
68.9
4
380
48,000
3
73.0
4
415
48,000
3
66.9
4
ELECTRIC
WATER
DRAINAGE
CLEARANCE
C
D
The Floor Drain must be located
outside the confines of the
equipment base.
1 1/2˝ I.P.S. common drain.
Do not connect other units to this drain.
Do not use PVC pipe for drain.
Cold Water Inlet
35 psi minimum
60 psi maximum
1/4˝ NPT
Condenser feed
3/8˝ NPT Boiler
feed
Right - 3”, Left - 3”,
Rear - 3” (12” on control
side if adjoining wall or
equipment is over 30” high
for service access)
Contact factory for
variances to clearances.