1333 East 179th St., Cleveland, Ohio, U.S.A. 44110
Ph
: 1-216-481-4900
Fx
: 1-216-481-3782
Web Site
: www.clevelandrange.com
Cleveland Range,
LLC
SINCE 1922
INNOVATIVE STEAM COOKING SOLUTIONS
Cook/Chill Systems
SECT.
XIV
PAGE
53
0402
COMPRESSED AIR SYSTEMS
& REFRIGERATED AIR DRYERS
ITEM NUMBER __________________________
JOB NAME / NUMBER __________________
COMPRESSED AIR SYSTEMS
Cleveland Standard Features
■
Air Compressor mounted on A.S.M.E. rated Receiver Tank
■
Baldor high efficiency Motor
■
Magnetic Starter with Thermal Overloads, completely wired
and mounted
■
Balanced Pump, external and internal
■
Cast Iron Cylinders
■
Forged Crankshaft and Pistons
■
High quality cast iron Piston Rings
■
Cast aluminum Finned Inner Coolers
■
Inner Cooler Safety Valve
■
Manual Drain for Air Receiver Tank
■
Automatic Start and Stop Control
■
14 gauge Belt Guard
■
1/2" Combination Filter/Pressure Regulator/Guage
■
80 gallon Receiver Tank for CAS-5 & CAS-7.5
■
120 gallon Receiver Tank for CAS-10
Options & Accessories
❐
Vibration Isolation Pads (set of four)
❐
3/4" Diameter Stainless Steel Flex Hose
❐
Refrigerated Air Dryer with 37˚F Dew Point
❐
Programmable, Automatic Drain Valve for Receiver Tank
Shall be CLEVELAND Model CAS-_____, COMPRESSED
AIR SYSTEM, consisting of Air Compressor & Receiver
Tank, ___ H.P. (horse power); High efficiency Baldor Motor
with magnetic Starter, Automatic Start and Stop Control;
balanced External and Internal Pump; 14 gauge Steel; Belt
Guard; 1/2" combination Filter / Pressure Regulator;
____ gallon Receiver Tank.
Short Form Specifications
REFRIGERATED AIR DRYERS
Cleveland Standard Features
■
Non-Cycling Dryer with double pass flooded Evaporator
■
Rated at 37
°
F (+20
°
F) Pressure Dew Point
■
High efficiency Shell and Tube designed Heat Exchangers
for Compact Unit size and weight
■
Low and High Refrigerant protection with Automatic
Shut-Down Device
■
Internal Thermal Overload Protection
■
Float operated Drain Valve
■
Power “on/off” Switch with Control Light
■
Low ambient Fan Control
■
Air cooled, compact design, cabinet type
■
Electrical Supply Cord
■
Designed for wallmounting
Shall be CLEVELAND Model CAS-AD__, _____, REFRIGERATED
AIR DRYER for Series “CAS” Compressed Air Systems. Rated at
37
°
F (+20
°
F) Pressure Dew Point; Air cooled cabinet type; com-
pact design with Shell and Tube Heat Exchanger; Automatic High
and Low Pressure Shut-Down device; Thermal Overload
Protection; Non-Cycling Dryer with double pass flooded
Evaporator; low ambient Fan Control; Float operated Drain Valve.
Short Form Specifications
CAS-10
CAS-7.5
MODELS
:
CAS-5
(VERTICAL)
CAS-7.5 (VERTICAL)
CAS-10
(HORIZONTAL)
MODELS
:
CAS-AD-25
CAS-ADA-40