background image

Statement of Responsibilities

This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service
Representatives who are familiar with both the safety procedures, and equipment they service.

Cleveland Range, LLC assumes no liability for any death, injury, equipment damage, or property damage
resulting from use of, improper use of, or failure to use the information contained in this document. 

Cleveland Range, LLC has made every effort to provide accurate information in this document, but
cannot guarantee that this document does not contain unintentional errors and omissions.

The information in this document may be subject to technical and technological changes, revisions, or
updates.

Cleveland Range, LLC assumes no liability or responsibility regarding errata, changes, revisions, or
updates.

Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to follow industry
standard safety procedures, including, but not limited to, OSHA regulations, and disconnect / lock out /
tag out procedures for all utilities including steam, and disconnect / lock out / tag out procedures for gas,
electric, and steam powered equipment and / or appliances

All utilities (gas, electric, water and steam) should be turned OFF to the equipment and locked out of
operation according to OSHA approved practices during any servicing of Cleveland Range equipment

Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to maintain up-to-date
knowledge, skills, materials and equipment.

Summary of Contents for 24-CGM-200

Page 1: ... technical and technological changes revisions or updates Cleveland Range LLC assumes no liability or responsibility regarding errata changes revisions or updates Qualified Cleveland Range LLC Authorized Service Representatives are obligated to follow industry standard safety procedures including but not limited to OSHA regulations and disconnect lock out tag out procedures for all utilities inclu...

Page 2: ... and the set time 115 VAC is sent through the optional door switch 115 VAC is sent to the condensate solenoid and cold water is sent to the condensate spray nozzle 115 VAC is sent to the steam solenoid and steam is sent to the cooking cabinet There the steam is directed around the product and pulled down the drain by the condensate spray When the cooking compartment reaches 193 degrees internally ...

Page 3: ......

Page 4: ...switch 115 VAC is sent to the condensate solenoid and cold water is sent to the condensate spray nozzle 115 VAC is sent to the steam solenoid and steam is sent to the cooking cabinet There the steam is directed around the product and pulled down the drain by the condensate spray 3 When the timer counts down in the timed position 115 VAC is removed from the condensate circuit 115 VAC is removed fro...

Page 5: ......

Page 6: ...Cleveland Range LLC 1333 East 179th St Cleveland Ohio U S A 44110 Ph 1 216 481 4900 Fx 1 216 481 3782 Visit our Web Site at www clevelandrange com ...

Page 7: ...ater indicator light 3 When the momentary amber switch is depressed 115 VAC is sent to the R1 relay closing it x The normally closed R1B contacts open de energizing the amber light x The relay latches itself through contacts 3 and 5 with a jumper to the coil x If either the high pressure switch opens or the low probe circuit on the water level board opens then the latch circuit opens x When the wa...

Page 8: ...ized x When the pressure drops below the set point the heat circuit is energized and the heat process begins again 7 Water continues to fill until the high probe is grounded x When the high probe is grounded the WF terminal on the water level board is de energized x The fill solenoid closes until the high probe is ungrounded for 5 seconds x If the water level drops below the high probe for more th...

Page 9: ...o the low probe shorting it to ground x 115 VAC is removed from the IND terminal and the low water indicator light is de energized x If the low water cut off float switch opens the low water indicator light re energizes x 115 VAC is sent from the HTR terminal to the normally open contacts of R2B x With water in the unit and the R2 relay energized 115 VAC is sent through the normally closed contact...

Page 10: ...W C 5 The water in the boiler is heated to steam x As steam is generated and pressure builds the air is pushed out through the steamtrap x When steam goes through the steam trap and heats it to 192 degrees it closes 6 Pressure builds in the boiler to the set point x The operating pressure switch opens and the heat circuit is de energized x When the pressure drops below the set point the heat circu...

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ...e the optional Secondary Low Water Cut Out With the High Limit pressure switch temporarily bypassed does the Amber light go off when the reset switch is depressed Yes No No Yes No Replace the high limit pressure switch With the SLWCO switch temporarily bypassed does the Amber light go off with the reset switch depressed No Yes Yes Replace the SLWCO switch With a jumper from terminal 6 to 4 on the ...

Page 15: ...ater leaving the fill solenoid Replace wiring to drain solenoid Does the steamer have the optional intermittent blowdown timer Replace the wiring to the intermittent blowdown timer Is there 120 VAC between terminals 2 3 on the timer Replace the intermittent blowdown timer Is there 120 VAC across the coil of the drain valve Is water draining from the generator If water is leaving the fill solenoid ...

Page 16: ...placing the ground wire to the burner ground terminal is there 1 5 micro amps DC to the ignition module No Is there flame at the burner Yes Yes No With spark and gas there should be fire Recheck the gas pressure and burners and igniter Yes Yes Replace the ignition wire No Boiler won t heat start PROBLEM Gas boiler won t ignite PROBLEM Gas Boiler Overfills Boiler over fills With the HI probe emerse...

Page 17: ...ler Stops Producing Steam Boiler stops steaming Does the amber light in the reset switch come on Is the temperature sensitive dot surrounded by a yellow circle on the water board white Replace the water board It has reached a temperature of over 180 degrees Yes No The ignition module has gone into lockout See Boiler won t ignite Does boiler have the optional Secondary Low Water Cut Out Yes Are the...

Page 18: ... on the TDS timer to prevent the purge from coming on To open the hand hole plate loosen and remove the nut and bar across the generator opening Place the end of a two x four on the hand hole plate Rap the end of the wood with a hammer in various places until the plate and gasket fall inside the generator Remove any scale build up that can be taken out by hand or with a small vacuum cleaner IF THE...

Page 19: ... 5 DO NOT PRESS THE AMBER STEAM SWITCH THIS CHEMICAL WORKS BEST WHEN COLD STEP 6 Wait 1 2 hours to allow for descaling of the generator Drain the generator by turning off the red POWER switch The drain and fresh water solenoid valves will open for three minutes allowing the generator to flush out After draining fill the generator with fresh water and repeat the flush process by turning off the pow...

Page 20: ...red power switch to fill the generator and then the amber switch when the light comes on After twenty 20 minutes the generator should have steam in it Check for steam leaks around the hand hole If any leaks are found repeat the process for replacing the gasket ...

Page 21: ...1333 East 179th Street Cleveland Ohio 44110 Phone 216 481 4900 Fax 216 481 3782 ...

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ......

Page 27: ......