User Manual: ZCARE : Warning Wristband
CLEODE
page
17
of
22
V.
Software interface
V.1
Presentation
The wristband ZCare is ZigBee® pro compliant, and Home Automation 1.2 compliant ZigBee® Alliance. It has
IASZone application and manages 2 alarms :
1)
A fall detection alarm
2)
A manual press alarm
V.2
ZCare Application
The signaling of an alarm is done by means of a comand IASZone cluster.
V.2.1
Application Description
•
Device ID : IAS Zone
•
Endpoint number : 1
•
Clusters :
Serveur
Customer
Basic (0x0000)
/
Power Configuration (0x0001)
/
Identify (0x0003)
/
Alarms (0x0009)
/
IAS Zone (0x0500)
/
Care Configuration (0xFC0A)
/
V.2.2
Clusters Description
The Clusters description and attributes managed by ZCare is as follow:
V.2.2.1
Cluster Basic
Attribute
Attribute ID
ZCLVersion
0x0000
ApplicationVersion
0x0001
StackVersion
0x0002
HWVersion
0x0003
ManufacturerName
0x0004
ModelIdentfier
0x0005
DateCode
0x0006
PowerSource
0x0007
LocationDescription
0x0010
PhysicalEnvironment
0x0011
DeviceEnabled
0x0012
AlarmMask
0x0013
V.2.2.2
Cluster Power Configuration
This cluster allows to config this low battery alarms and to have an information of the battery value. The attributs
follows are managed:
Attribute
Attribute ID
BatteryVoltage
0x0020
BatteryAlarmMask
0x0035
BatteryVoltageMinThreshold
0x0036