background image

 

 

PV-ezRack Solar Terrace II_Planing and Installation Guide_V1.3 

Page 11 of 11

 

 

11/20 Duerdin St 

 

 

Tel: +61 3 9017 6688 

Clayton VIC 3168, Australia    

 

 

Fax: +61 3 9017 6668 

www.clenergy.com.au 

 

Email: [email protected] 

 

 
10 Years Standard Warranty Terms and Conditions 

20 Year Designed Service Life 

 

Clenergy  international co. Ltd warrants to the original purchaser (“Purchaser”) 

of  product(s)  that  it  manufactures  (“Product”)  at  the  original  installation  site 

that the Product shall be free from defects in material and workmanship for a 

period  of  ten  (10)  years,  except  for  the  anodised  finish,  which  finish  shall  be 
free  from  visible  peeling,  or  cracking  or  chalking  under  normal  atmospheric 

conditions  for  a  period  of  five  (5)  years,  from  the  earlier  of  1)  the  date  the 

installation of the Product is completed, or 2) 30 days after the purchase of the 

Product by the original Purchaser (“Finish Warranty”).

 

The  Finish  Warranty  does  not  apply  to  any  foreign  residue  deposited  on  the 
finish.  All  installations  in  corrosive  atmospheric  conditions  are  excluded.  The 

Finish  Warranty  is  VOID  if  the  practices  specified  by  AAMA  609  &  610-02 

 

“Cleaning  and  Maintenance  for  Architecturally  Finished  Aluminium” 

(www.aamanet.org)  are  not  followed  by  Purchaser.  This  Warranty  does  not 

cover  damage  to  the  Product  that  occurs  during  its  shipment,  storage,  or 
installation. 

This  Warranty  shall  be  VOID  if  installation  of  the  Product  is  not  performed  in 

accordance with Clenergy’s written installation instructions, or if the Product has 

been modified, repaired, or reworked in a manner not previously authorized by 

Clenergy IN WRITING, or if the Product is installed in an environment for which 
it was not designed. Clenergy shall not be liable for consequential, contingent or 

incidental damages arising out of the use of the Product by Purchaser under any 

circumstances.  
If within the specified Warranty periods the Product shall be reasonably proven 

to be defective, then Clenergy shall repair or replace the defective Product, or 

any part thereof, in Clenergy’s sole d

iscretion. Such repair or replacement shall 

completely  satisfy  and  discharge  all  of  Clenergy’s  liability  with  respect  to  this 

limited  Warranty.  Under  no  circumstances  shall  Clenergy  be  liable  for  special, 
indirect or consequential damages arising out of or related to use by Purchaser 

of the Product. 
Manufacturers of related items, such as PV modules and flashings, may provide 

written  warranties  of  their  own.  Clenergy’s  limited  Warranty  covers  only  its 

Product, and not any related items. 

 

 

Summary of Contents for PV-ezRack SolarTerrace II

Page 1: ... 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au PV ezRack SolarTerrace II Code Compliant Planning and Installation Complying with AS NZS1170 2 2011 Amdt 3 2013 Contents 1 Introduction 2 2 Installation Tools Components 3 3 Installation Guide 7 4 Service 11 ...

Page 2: ...equate and will meet the local standards During the installation and especially when working on the roof inform yourself about the appropriate safety regulations and please also pay attention to the relevant regulations of your local region Please check that you are using the current version of the installation manual by contacting Clenergy Australia by email on sales clenergy com au or your local...

Page 3: ... 9017 6668 www clenergy com au Email sales clenergy com au 2 Installation tools components 1 Installation tools Hydraulic Pile Driver Allen Key Power Tool Maximum torque M8 20N m M10 30N m M12 50N m Adjustable Spanner String 2 Components list Overview of system components End Clamp Middle Clamp T Rail Rail Clamp Girder Post Head C Post Post Brace ...

Page 4: ... Installation Guide_V1 3 Page 4 of 11 11 20 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au 3 Overview of system components T Rail Girder Post Head Post Brace Post ...

Page 5: ... Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au 4 Mounting of the single assembly groups Step 1 Pole grounding Step 2 Mounting top and side brackets Step 3 Fixing the structure Step 4 Mounting the T Rails Step 5 Module mounting ...

Page 6: ...0 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au Angle positioning STII Panel dimension up to 1 7m Wind Zone Region A Region B Region C Region D Wind Speed m s 41 48 56 66 Leg Spacing m 3 3 2 85 2 05 1 45 ...

Page 7: ...steps installation Instruction 1 Install the Open Post Before the installation prepare all the products and installation tools that will be needed Confirm the hydraulic pile driver can be used at the site Mark the Open Posts array perimeter Drive the piles into the earth Use a string to make sure all the piles are in a same line and height 2 Mount Post Head Install the Post Head fix with Hexagonal...

Page 8: ...y com au Email sales clenergy com au 3 Mount Post Brace Insert the Post Brace on one side of Post Then fold it and fix it to the post with Hexagonal Bolt and Nut 4 Attach the Girder Attach the Girder on to the Post Head The fixing arm in the Post had will click on to the bolt on the Girder Connect the Support Tube to the Post Brace and fix using Hexagonal Bolt and Nut ...

Page 9: ... 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au After installing the Girder adjust the system to make sure all the Tri groove Beams are in a same line and height Notes Make sure the Tri groove Beams are all positioned the same before installing the T Rail ...

Page 10: ...com au Email sales clenergy com au 5 Mount the rails Mark the panel array perimeter and attach the T Rail to Tri groove Beam with one T Rail Clamp on each side 6 Mount the panels Install the panels by using the patented Clenergy End Clamps and Inter Clamps Fasten them by Hexagonal Bolt using 15 20Nm torque End Clamp Middle Clamp The installation of the panels is completed ...

Page 11: ...inished Aluminium www aamanet org are not followed by Purchaser This Warranty does not cover damage to the Product that occurs during its shipment storage or installation This Warranty shall be VOID if installation of the Product is not performed in accordance with Clenergy s written installation instructions or if the Product has been modified repaired or reworked in a manner not previously autho...

Reviews: