BNP 65 and 220 SUCTION BLAST CABINETS
Page 7
© 2016 CLEMCO INDUSTRIES CORP.
www.clemcoindustries.com
Manual No. 21309, Rev. I 06/16
Figure 7
2.5.2 Three-phase
wiring
NOTE: a wiring schematic is packed inside the cabinet’s
control panel. After wiring is completed, keep a copy of
the schematic with the manual for future reference and
for electrical replacement parts.
2.5.2.1
Refer to the wiring schematic stowed inside the
control panel mounted on the cabinet and wire from the
users disconnect to the panel and from the panel to the
dust collector motor, per instruction on the motor data-plate.
2.5.2.2
Check the amperage on initial start up; if the
motor draws excessive amperage, gradually close the
dust collector damper, located on the inlet on CDC dust
collectors, and on the exhauster outlet on RPC and RPH
dust collectors, until the amperage is within the
specifications shown on the motor plate.
2.5.3 Check motor rotation
2.5.3.1
After wiring is completed, observe the warning
that follows and check the motor rotation. To check
rotation, turn the On-Off switch ON and quickly turn it
OFF, causing the motor to rotate slowly. Look through the
slots in the motor fan housing where rotation of the fan
can easily be observed. Proper rotation is indicated by the
arrow on the exhauster housing; the fan should rotate
toward the exhauster outlet. If it rotates in reverse, change
the wires as noted on the motor plate to reverse rotation.
WARNING
Do not look into the exhauster outlet while the
paddle wheel is turning. Injury to the eye or face
could occur from objects being ejected from the
exhauster.
2.6
Cabinet Air-Inlet Damper, refer to Figure 8
2.6.1
The air-inlet damper is located on the top of the
cabinet and must be set to match the cabinet
dimensions and reclaimer size. The air-damper was
preset prior to shipment; confirm the initial setting as
noted below.
Figure
8
2.6.2
The label on the damper show the settings in
degrees. The initial setting should align the handle as
follows.
65 with 300 reclaimer ... align handle to 30 degrees
65 with 600 reclaimer ... align handle to 30 degrees
65 with 900 reclaimer .. align to 0 degree (full open)
220 with 600 reclaimer ... align handle to 30 degrees
220 with 900 reclaimer .. align to 0 degree (full open)
2.6.3
Loosen the lock nuts and align the damper
handle as noted. When correctly positioned, tighten the
lock nuts to maintain the setting. Refer to Section 5.6 for
adjustment procedure.
Damper Handle
Degrees Label
Align handle to degrees
as noted above
Air-Inlet Damper
115 VOLT, 1PH WIRING FOR CABINET AND DUST COLLECTOR MOTOR