12
Defective gaskets.
The following gaskets should be
checked for wear and replaced:
Impact separator.
Dust collector.
(9) Suction unit cannot be turned
on.
No air supply.
Install an air supply.
Defective inlet valve RMS-1500. Check and repair or replace if
necessary.
Defective pneumatic controls.
Check all control hoses and
connections for wear.
Check 3-way slide valve.
7 Replacement parts
7.1 System
(See Figure 2 -
Replacements parts HS 200 P-1.)
No. Stock No.
Model
Description
(-)
99954D
HS-200 P-1
Dustfree, portable blast machine complete
(1)
90545D
HMS
Moisture separator
(2)
100028
RMS-1500
Inlet valve complete
(3)
01906D
Pressure regulator 1
¼
"
(4)
02321D
P-2
Pop-up valve with external sleeve
(5)
99157D
P-5
Gasket
(6)
03371I
TLR
Outlet valve
(7)
100047
1”
Hose with SKG-25
(8)
02397D
1 ¼”
Ball valve
(9)
22780D
QK-Quantum
Abrasive metering valve
(-)
100832
Gasket (for impact separator)
(10)
99802D
Screen HSP
(11)
90554D
1 ½”
Ball valve
(12)
99702D
2"
Nipple 2” A
(13)
99180D
2"
Coupling
(14)
04351D
19 x 7
Blast hose 10 m
(-)
04305D
25 x 7
Blast hose 10 m
(15)
90067D
2"
Suction hose (PU)
(16)
94342D
EDBH-90-I
Blast head without nozzle