Industrial Ethernet Unmanaged
7
Rear Panel View with DIN rail and Wall Mounting Brackets
(common rear view, may vary with model)
Models
SSF-1x2-RUGGED
SSF-1x4-RUGGED
DIN Rail Mounting Procedure
All Industrial switches from the SSF-RUGGED series have DIN rail bracket mounted
from factory to the rear panel of the unit. If Wall mounting is needed, please first
remove the DIN rail bracket. If DIN rail bracket needs to be reattached, please
make sure the spring is located on top position when unit is vertical.
Step 1
Step 2
Please hold unit as in below image,
making sure top of bracket with spring
falls onto the top edge of TS-35 DIN rail
Rotate and snap the unit onto the DIN
rail by pushing the bottom unto the TS-
35 DIN rail. Unit will be secured to rail.
To remove unit from rail, please repeat procedure in reverse. Start by pulling out
the bottom of unit from the DIN rail.