Operation
6.1 General Information
The controls directly on the socket tray are restricted to:
•
Switching on and off
•
Removing and replacing the sockets
•
Observing the corresponding instructions on the status
LEDs and the LCD.
The nutrunner control gives user guidance:
•
via the status LEDs on the inserts for the sockets
•
optionally via the LCD
For the purpose of diagnosis, a submenu can be called up
with the right function key <F2>.
See chapter
The connection is made using WLAN. Set the WLAN con-
nection can be configured with the
LiveWire RF Settings
program. See chapter
.
The WLAN settings are stored on a LiveWire Memory Chip
(LMC). To transfer the settings to a new socket tray in the
event of a socket tray failing, change the LMC.
6.2 Switching on/off
Switching on
To switch the socket tray on, briefly press the <on/off
switch>.
Switching off
After the boot process has ended, the socket tray can be
switched off.
It can only be switched off when the system is in the state
Status
. If the system is in the main menu or the submenus,
press and hold the function key <F1> for two seconds to
exit the menu level.
To switch the socket tray off, press the <on/off switch> and
hold it for longer than two seconds. As soon as the LCD
shows
Manual OFF
, release the <on/off switch> to switch
the socket tray off.
6.3 Initialization error
During the initialization phase, the software examines and
initializes the connected components. If any faults are
detected during the initialization phase, the message:
Init. failed
appears.
Note
Remove the battery to store the socket tray.
Fault
Possible
cause
Measure
LMC- error
→Control of
the socket
tray is not
possible.
The LMC can-
not be read or
is not found.
Replace the LMC.
WLAN initial-
ization failure
→WLAN con-
nection is
essential.
Initialization of
WLAN mod-
ule failed.
Have the WLAN
module exchanged
by Service.
Extension
board error
→Control of
the socket
tray is not
possible.
Difference
detected
between pro-
grammed and
actual num-
ber of exten-
sion boards.
Call up the test
function
Ext. board
to check how many
extension boards
have been found.
If not all boards are
found, open the
socket tray and
check the connec-
tions. If the error
cannot be cor-
rected, contact the
service of the
Apex Tool Group.