Cleco LiveWire 943610PT Instruction Manual Download Page 16

16

P2332BA | 2019-08

Apex Tool Group

7

EN

7.3 Main menu

 

Warning message

If there is no more activity on the socket tray, a countdown 
appears on the display. This indicates the remaining time 
until the socket tray shut off. If new activities are carried out 
on the socket tray during this time, the countdown is inter-
rupted and starts again from the beginning. 

However, if the warning message 

Batt. low

 is displayed, 

the countdown until power is switched off is no longer inter-
rupted.

Both warning messages can be set via the control software 
used.

7.4 Submenu

To change from the main menu to the diagnosis menu, 
press the On-/Off button or the function key <F2> and hold 
it for two seconds. To exit the diagnosis menu and return to 
a higher menu level, press the function key <F1> and hold 
it for two seconds.

To select menu items, press the <on/off button>. There are 
different submenus.

7.4.1 Administration submenu

 

7.4.2 Diagnostics submenu

Diagnostics

Diagnostic functions for the socket tray.

Administration

Displays general points such as serial 
number, software version ….

LMC

Shows the 

LiveWire Memory Chip 

set-

tings.

Wireless transmission

Shows settings of wireless transmission

.

Warning time befor shut off
Displays the countdown before shut off.

Battery low
Displays a warning message when the 
battery voltage falls below a defined 
limit.

In this case, recharge battery or replace 
it with one that is already charged.

>Main
Diagnos-
tics

>Main
Adminis-
tration

>Main 
LMC

>Main 
Wireless 
WLAN

Power 
down
mm:ss

Batt.
low

Serial number

Display of serial number.

Controller software version

Displays the installed software version.

Hardware configuration
Number of programmed initiators and 
status LEDs.

Voltages

Second line: Current battery voltage. If 
the voltage drops below limit, a warning 
is output on the socket tray. 
Third line: Programmed value. 

LED test

The functional readiness of the status 
LEDs can be visually checked with the 
LED test. All status LEDs light up briefly 
in different colors. 

To activate the function, press the 
On/Off button.

S/N
000000
245

Vers.
V1.00.
00

HWkonf
Ini    08
LED 08

Voltage
V26.40
U19.00

Lamp 
test

Summary of Contents for LiveWire 943610PT

Page 1: ...For additional product information visit our website at www ClecoTools com Instruction Manual P2332BA 2019 08 943620PT 943610PT WLAN socket tray...

Page 2: ...able language or transmitted on electronic mechanical optical or other media without the express permission of the Apex Tool Group Disclaimer Apex Tool Group reserves the right to modify supplement or...

Page 3: ...ation 10 4 3 Charge battery pack 10 4 4 Installation 10 5 Commissioning 11 5 1 Opening the housing 11 5 2 Configuring the socket tray 11 5 2 1 Installing the USB interface driver 11 5 2 2 Installing t...

Page 4: ...4 P2332BA 2019 08 Apex Tool Group EN 8 Troubleshooting 19 9 Technical Specifications 21 9 1 General Information 21 9 2 Mechanic dimensions and weights 21 10 Service 21 11 Disposal 21...

Page 5: ...operation of this equip ment Other documents Symbols in the text Number Type P1970E Operating Manual Battery Pack 935377 P2372JH EC Declaration of Conformity P3315C Installation instructions S168688 L...

Page 6: ...a hammer impact tool with outside control or battery Only use Apex Tool Group battery charger 24 V 935391 for charging Power supply Operation with 26 V battery pack 935377 a 44 V battery pack 936400PT...

Page 7: ...he control and function elements Fig 3 2 External control and function elements Fig 3 3 Internal control and function elements Features 943620PT 943610PT Number of inserts 4 8 Select App 1 to 4 1 to 8...

Page 8: ...The MAC address is defined by Cleco Production Tools and cannot be changed The other data can be changed with LiveWire RF Configuration software via USB connection to the PC 3 3 7 Wireless module The...

Page 9: ...10PT 1 Pos 17 page 7 0 2 Pos 18 page 7 1 Component Battery pack li ion 26 V Order No 935377 Battery pack li ion 44 V Order No 936400PT Power Module PM48 Order No 961350PT LiveWire Memory Chip LMC Orde...

Page 10: ...Inserts 4 3 Charge battery pack The battery pack is only partly charged upon delivery Fully charge the battery before using it for the first time See battery pack instruction manual P1970E 4 4 Install...

Page 11: ...nternal control and function elements Seite 7 position 14 3 Switch on the socket tray 4 Plug the USB connector cable into the mini USB socket on the controller board and connect it to the PC 5 A suita...

Page 12: ...ace port selected when the USB driver was installed This inter face port can be viewed in the Windows Device Man ager Fig 5 2 Properties of USB serial port COM4 2 Settings for the following can be mad...

Page 13: ...a little longer about five seconds the first time it is switched on after the firmware download When the firmware has been flash stored the red and green LED display flash After flash storing the boot...

Page 14: ...ate Status If the system is in the main menu or the submenus press and hold the function key F1 for two seconds to exit the menu level To switch the socket tray off press the on off switch and hold it...

Page 15: ...evaluates the status of the initiators Connection lost A connection to a nutrunner control exists However the nutrunner control has not commu nicated with the socket tray again within the pro grammed...

Page 16: ...unctions for the socket tray Administration Displays general points such as serial number software version LMC Shows the LiveWire Memory Chip set tings Wireless transmission Shows settings of wireless...

Page 17: ...oards MAC address MAC address display Serial number Serial number display Country code Various WLAN frequency ranges are available World worldwide approved US CA approved in the USA EU approved in Eur...

Page 18: ...of access point Transmission output Transmission output display Channel used Display of channel currently used Channels scanned Display of channels scanned UDP TCP communication protocol Selection of...

Page 19: ...uration of the expansion board s incorrect Contact Sales Service Centers of the Apex Tool Group LMC is not readable Change LMC LMC is not available Insert LMC Initialization of the WLAN module failed...

Page 20: ...tings submenu Port 4001 is disabled by a firewall Configure the firewall such that the required IP MAC addresses can use port 4001 The wireless channel at the access point is out side the range suppor...

Page 21: ...ditions Storage temperature 25 C to 70 C Remove the battery to store the socket tray Ambient temperature 0 C to 45 C Permissible relative humidity 0 90 without condensa tion Electrical specifications...

Page 22: ...x Tool Group GmbH C O Spline Gauges Piccadilly Tamworth Staffordshire B78 2ER United Kingdom Phone 44 1827 8727 71 Fax 44 1827 8741 28 FRANCE Apex Tool Group SAS 25 Avenue Maurice Chevalier ZI 77330 O...

Reviews: