Page 1: ...UV Cabinet ...

Page 2: ......

Page 3: ...SL UVCAB CSL UVCABMIDI CSL UVCABMINI CSL UVCABTY4 CSL UVCABMIDITY4 CSL UVCABMTY4 Record the following for your records Model _____________________ Catalogue No _____________________ Date of Delivery _____________________ Warranty Period _____________________ Serial No _____________________ Invoice No _____________________ Purchase Order No _____________________ ...

Page 4: ...rmation 3 UV Light Safety Information 4 Usage Guidance and restrictions 4 Packing List 5 Specifications 6 Operating Instructions 7 Installation 7 Operation UV Sterilisation 7 Operation White Light 7 Care and Maintenance 8 Cleaning UV Sterilization Cabinets 8 Replacing the Lamps 9 Warranty 10 ...

Page 5: ...t in this instruction manual Anyone intending to use this equipment should read the complete manual thoroughly These units comply with the following European directives 2006 95 CE Low Voltage Directive and 2014 30 UE official Title 2004 108 EC EMC Electromagnetic Compatibility By virtue of the following harmonised standards BS EN IEC 61010 1 2010 Safety Testing of Lab Equipment BS EN IEC 61326 1 2...

Page 6: ... switches on the doors will instantly turn off the UV lights when the doors are opened Usage Guidance and restrictions Maximum altitude 2 000m Temperature range between 4 C and 65 C Maximum relative humidity 80 for temperatures up to 31OC decreasing linearly to 50 relative humidity at 40OC Not for outdoor Use This apparatus is rated POLLUTION DEGREE 2 in accordance with IEC 664 POLLUTION DEGREE 2 ...

Page 7: ...CABTY4 CSL UVCAB 110V UVCAB CSR TY4 CSL UVCABMIDITY4 CSL UVCABMIDI 110V UVCAB CSR TY4 CSL UVCABMTY4 CSL UVCABMINI 110V UVCAB CSR TY4 Packing List Checked by ________________________ Date ________________________ The packing lists should be referred to as soon as the units are received to ensure that all components have been included The unit should be checked for damage when received Cleaver Scien...

Page 8: ...INI Size H x W x D cm 77 x 58 x 42 62 x 58 x 42 45 x 58 x 35 Working Area H x W x D cm 60 x 53 x 41 42 5 x 53 x 39 27 x 53 x 32 Mains Fuse 2 5 Amp 2 5 Amp 2 5 Amp White Light 15 W 15 W 15 W UV Light 4 x 15W Germicidal 4 x 15W Germicidal 4 x 15W Germicidal Weight 19 Kg 14 6 Kg 12 Kg ...

Page 9: ...eration UV Sterilisation 1 Place the objects to be sterilized inside the cabinet and close the side doors PLEASE NOTE the UV lights will not operate when the doors are open 2 Switch the Power switch to the ON position 3 Turn the timer to the required time Twenty minutes is sufficient time to sterilize most pieces of equipment The UV lights will automatically turn on and then switch off after the s...

Page 10: ...e the light unit and bulbs The units should never come into contact with the following cleaning agents these will cause irreversible and accumulative damage Acetone Phenol Chloroform Carbon tetrachloride Methanol Ethanol Isopropyl alcohol Alkalis DO NOT use abrasive creams or scourers Components should always be dried with clean tissues prior to use The cabinet should not be used on or above surfa...

Page 11: ...e cooled down before removing them 1 Remove the mains lead from the back of the unit 2 To remove the lamps open both safety doors fully and using both hands twist the lamps one quarter turn The lamps will then come out of their sockets 3 To insert new lamps place the lamps in their sockets and twist them until they fix in position 4 Replace the mains lead and have the cabinet checked by a qualifie...

Page 12: ...e other than CSL or an appointed distributor or representative are no longer under warranty from the time the unit was modified Units which have accessories or repaired parts not supplied by CSL or its associated distributors have invalidated warranty CSL cannot repair or replace free of charge units where improper solutions or chemicals have been used For a list of these please see the Care and M...