background image

>

SPECIFICATIONS

CONVERGE PRO 8i

DATA SHEET

<

>

CLEARONE LOCATIONS

>

CONVERGE PRO 8

i

BACK PANEL

Audio Performance

Conditions: Unless otherwise specified, all

measurements are performed with a 20 Hz
to 22 kHz BW limit (no weighting)

Frequency Response: 20 Hz to 22 kHz ±1dB
Noise (EIN): -126 dBu, 20 kHz BW, max gain,

Rs=150 

Ω

THD+N: <0.02%
Dynamic Range: 100 dB (non A-weighted)
Crosstalk <-91 dB re 20 dBu @ 20 kHz

channel to channel

Auto Mixer Parameters

Number of Open Microphones (NOM)
PA Adaptive Mode
First Mic Priority Mode
Last Mic Mode
Maximum # of Mics Mode
Ambient Level
Gate Threshold Adjust
Off Attenuation Adjust
Hold Time
Decay Rate

Matrix Mixing Parameters

36x24 matrix
12 analog in/out
12 expansion bus in/out
8 assignable processing blocks in/out
4 assignable fader blocks in/out

Assignable Processing Blocks

Filters:

All pass
Low pass
High pass
Low shelving
High shelving
Parametric EQ
Notch
CD Horn

Crossovers:

Bessel
Butterworth
Linkwitz-Riley

Compressor
Delay; adjustable up to 250 ms

Assignable Fader Blocks

Gain/Mute

Microphone Input Configuration

Input Gain Adjust
Mic or Line Level
Phantom Power on/off
Echo Cancellation on/off
Noise Cancellation on/off
Filters:

All Pass
Low Pass
High Pass
Notch
PEQ

Mute on/off
Chairman Override on/off
AGC on/off
Automatic Level Control on/off
Auto Gate/Manual gate
Adaptive Ambient on/off
Pre AEC channel

Mic/Line Inputs 1-8

Push-on mini-terminal block, balanced,

bridging

Impedance: < 5 KΩ
Nominal Level: adjustable -56 dBu to 0 dBu 
(7 dB step coarse gain adjustment)
Maximum Level: -65 dBu to +20 dBu
Echo Cancellation: 130 ms tail time (works

with 12 dB of room gain)

Noise Cancellation: 6–15 dB attenuation
Phantom Power: 24 V, selectable

Line Inputs 9-12

Push-on mini-terminal block, balanced,

bridging

Impedance: < 5 KΩ
Nominal Level: 0 dBu
Maximum Level: 20 dBu

Expansion Bus In/Out

Proprietary Network
RJ-45 (2), 1.9 Mbps
Category 5 twisted-pair cable 200’ maximum

cable length between any two Converge Pro
products

Ethernet

Autoswitching with Quality of Connection

(QoC)

10/100 Mbps Ethernet Network Port
10/100 Mbps Ethernet PC Port
RJ-45 Connectors

RS-232

Serial Command Protocol Only (Console

software not supported on RS-232 port)

DB-9 female
9,600/19,200/38,400/57,600/115,200 baud

rate; 8 bits, 1 stop, no parity

Hardware flow control on (default)/off

USB

Version 2.0 compatible
Type B connector

Control/Status

DB-25 female A/B (2)
Inputs A/B: active low (pull to ground)
Outputs A/B: open collector, 40 VDC max, 

40 mA each

+3.3 VDC pins (2) (300 mA over-current

protected)

Configuration & Administration Software

Converge

TM

Console

Power Input Range

Auto-adjusting
100–240 VAC; 50/60 Hz

Power Consumption

30 W Typical

Dimensions (L x D x H)

17.25" x 10.25" x 1.75"
43.8 x 26 x 4.5 cm

Weight

7.5 lbs/3.3375 kg unit weight
12 lbs/5.4kg shipping weight

Operating Temperature

14° F/-10° C to 122° F/50° C ambient unit

temperature

Approvals & Compliance

AES48 compliant (audio equip grounding)
U.S.A. & Canada

CSA safety listed

EU Countries

RoHS compliant
WEEE compliant

See product manual for additional details

Optional Accessories

Converge Pro 880
Converge Pro 880T
Converge Pro 840T
Converge Pro TH20
Converge SR 1212

Tabletop Controller
Button Microphone – Omni-Directional
Button Microphone – Uni-Directional
Delta Microphone
Tabletop Microphone – Uni-Directional
JBL Wall-Mount Speakers

Part Number

910-151-810 Converge Pro 8i – 8-channel AEC
Microphone Mixer (no outputs)

Headquarters: 
Salt Lake City, UT USA 

5225 Wiley Post Way
Suite 500
Salt Lake City, UT 84116 

Tel:

801-975-7200 

Toll Free: 800-945-7730 

Fax:

801-977-0087

[email protected]

Latin America  

Tel:

801-974-3621

[email protected]

EMEA

Tel: 

44 (0) 1189 036 053

[email protected]

APAC  

Tel:

801-303-3388 

[email protected]

+

Other product names may be registered trademarks of their respective owners who do not necessarily endorse ClearOne or ClearOne’s products. All rights reserved. Information in this document subject to change without notice

© 2007 ClearOne Communications Inc. 802-151-810 Revision 1.7 January 2008.