ClearOne 910-3200-302 Quick Start Manual Download Page 5

QUICK-START GUIDE

3

MOUNT THE USB EXPANDER

The USB expander can be mounted in 1) a rack shelf , 2) under the table, 
3) on the wall, 4) above the ceiling. Each mounting type is explained 
below. Mounting hardware is not provided.

r

ack

 s

helf

 M

ountIng

ClearOne offers a standard 1U rack shelf with 20lb (9kg) weight capacity. 

ClearOne 1U Rack Shelf

(Part No. 910-6106-001)

1.  Determine location for rack shelf.
2.  Align mounting holes on rack shelf mounting ears with holes on the 

rack (at determined location).

3.  Insert the four #10-32 screws included with the ClearOne 1U rack 

shelf (or proper screws for your 3

rd

-party mount) and tighten.

NOTE:

 Remove pre-installed mounting ears on expander to fit up to 3 

expander units side-by-side on a single ClearOne 1U rack shelf.

4.  Torx drive screws secure the pre-installed mounting ears to the 

main body of the expander unit. Remove them with a Torx T15 
screwdriver. (optional)

Summary of Contents for 910-3200-302

Page 1: ...CONVERGE Pro 2 USB Expander unit A USB audio interface device for CONVERGE Pro 2 Quick Start Guide...

Page 2: ...Required 2 QUICK START OVERVIEW 2 MOUNT THE USB EXPANDER 3 Rack Shelf Mounting 3 Mounting Under The Table 4 Mounting On The Wall 5 Mounting Above The Ceiling 5 CONNECTIONS 6 Back Panel 7 Front Panel 8...

Page 3: ...stems It is not compatible with first generation CONVERGE Pro UNPACKING Parts Included The following items are included with the CP2 USB Expander CP2 USB Expander Unit 1 Qty 3 81mm Terminal Block Conn...

Page 4: ...l 4 Qty 6 or M3 5 screws 4 Qty Wall fasteners appropriate to the wall ceiling material T15 Torx screwdriver Tools Required The following tools are required to install the USB expander QUICK START OVER...

Page 5: ...6106 001 1 Determine location for rack shelf 2 Align mounting holes on rack shelf mounting ears with holes on the rack at determined location 3 Insert the four 10 32 screws included with the ClearOne...

Page 6: ...ring the expander s Mounting Under The Table Mounting hardware is not provided Select your own hardware based on your specific installation needs 1 Determine location for the mount 2 Using expander as...

Page 7: ...les 6 Insert four 6 or M3 5 screws and tighten NOTE Anchors and screws used to mount the expander are not provided and must be selected by installer for the type of wall material supporting the expand...

Page 8: ...nector 2 Remove affected ceiling tile and adjacent tiles required for access 3 Install fasteners anchors 4 Install expander unit at determined location 5 Use drywall saw to cut hole into finished side...

Page 9: ...The P Link In and Out ports enable you to connect with a CP2 unit or other P Link devices P Link connections carry power control and audio through CAT5e or CAT6 cable When not supplying power to an e...

Page 10: ...g normally Flashing Blue Locate mode initiated from CP2 Console Software Red Error condition Detailed instructions on using the Locate function in the CP2 CONSOLE software can be found in the CONVERGE...

Page 11: ...f the software setup include Create a new or open an existing project Add a CP2 and peripheral devices to a project Configure stack device settings Configure and manage Room Space settings Add USB to...

Page 12: ...200 204 150 150 Ft RJ45 CAT6 Cable 910 3200 204 200 200 Ft RJ45 CAT6 Cable CONTACT INFORMATION Headquarters 5225 Wiley Post Way Suite 500 Salt Lake City UT 84116 Sales Tel 801 975 7200 e mail sales cl...

Reviews: