5.
6.
7.
8.
9.
Test and verify signal performance is as expected via Link Loss Budget analysis. Remove or add attenuators as
needed to maintain proper power margin.
Upon successful completion of Step # 5, manually switch the Network Element to “Protect” and verify valid switch via
PM (Performance Monitoring) analysis.
Upon successful completion of Step # 6, perform steps 3-5 as above applied to the TX (Working) and RX (Working)
fiber pair.
Upon successful completion of Step # 7 and verification that the “Working” path is properly operating via PM Analy
-
sis, manually switch live traffic back to “Working” and retest via PM one last time. Insure that all alarms clear and that
traffic is operating normally.
(Optional) Insert a Near End QRSS (Quasi Random Signal Source) VT/STS (Virtual Tributary/Synchronous Trans
-
port Signal) level simulated traffic hard loop at the far end and then monitor the BER during exercise, and/or force a
manually switch to “Protect” to re-confirm proper operation.