Technical Specifications

Description

Application

24 Port Outdoor Wall Box

48 Port Outdoor Wall Box

Dimensions

12.52” H x 16.22” W x 5.75” D

12.52” H x 18.92” W x 7.26” D

Port Density

Up to 24 ports

Up to 48 ports

Cassette Types 

Supported

Clearview Blue

Connector Types SC/UPC, SC/APC, LC/UPC, LC/APC, FC/UPC, FC/APC, ST/UPC, MPO
Cable Types

Indoor/Outdoor, Outdoor (Riser/Non-Rated), Outdoor Armored (Riser/Non-Rated)

Splice Capacity

12 or 24 splice configurations in each Clearview Cassette

Storage Capacity

One meter of 900 μm fiber and up to 20 feet buffer tube

Material

16 gauge cold rolled steel (zinc chromate with almond powder coating)

The FieldSmart FDP 24 and 48 Port Outdoor Wall Boxes are 

ideal for both residential MDUs and business-class 

environments. Configurable for either patch only, patch and 

splice (Clearfield’s in-cassette splicing solution) or MPO 

plug-and-play, Outdoor Wall Boxes support all cable scenarios 

for the outside plant. The OSP platform is designed for the 

harshest environments, supporting NEMA 4 performance 

requirements, while providing conduit entry through field-

deployed knock-outs on both the rear and bottom of the unit. 

Additional applications include fiber demarcations, entrance 

facilities, and security systems (CCTV).

Designed from conception to provide fast and easy fiber jumper routing with ease of access to all circuits, the FieldSmart 

FDP Outdoor 24 and 48 Port Wall Boxes are craft-friendly, keeping the installer’s needs for quick deployment, intuitive use 

and ease of maintenance as the top priorities. Utilizing the Clearview

®

 Cassette, the box easily scale from 12 to 48 ports 

with the industry standard adapter of choice. Ring cut or mid-span capabilities allow distribution cables to be daisy-chained 

and for fiber hand-off through the riser, while a swinging bulkhead provides rear-access to cassettes and protects sub-unit 

slack storage. With lockable doors for added protection and a solid enclosure design to protect fiber terminations from 

damage, the FieldSmart Fiber Delivery Point (FDP) Wall Box product line provides superior fiber management for outdoor               

environments.

Summary of Contents for FieldSmart 48

Page 1: ...FieldSmart Fiber Distribution Point FDP 24 48 Port Outdoor Wall Box Installation Manual _____________________________________________________ Manual 020012 REV A Aug 2018...

Page 2: ...___________________________________ Manual 020012 REV A Aug 2018 Table of Contents Application 3 Description 3 Technical Specifications 3 Outdoor Wall Box Components 4 Wall Box Installation 5 Wall Box...

Page 3: ...ette splicing solution or MPO plug and play Outdoor Wall Boxes support all cable scenarios for the outside plant The OSP platform is designed for the harshest environments supporting NEMA 4 performanc...

Page 4: ..._________________________________________________ Manual 020012 REV A Aug 2018 Outdoor Wall Box Components 1 Can Wrench Accesible Security Doors 2 2 Conduit Opening 3 Slack Storage for Incoming Jumper...

Page 5: ...l 020012 REV A Aug 2018 Wall Box Installation The wall box is installed via the 4 holes located on the tabs on each corner of the rear of the enclosure Hold the wall box up to the mounting surface and...

Page 6: ...___________________________________________________ Manual 020012 REV A Aug 2018 Wall Box Access The interior of the wall box can be accessed by loosening the security screws on each of the two doors...

Page 7: ...ealcons and an assortment of rubber inserts grommets Choose the insert that is close to but larger than the size of the cable Compression Fitting Grommet Cable Size Inches Small Black Grommet 0 3 0 4...

Page 8: ...f the sealcon is present before installation O Ring The sealcon can then be installed by inserting the thread through the bottom of the wall box and securing with the included lock nut Figure 1 Note T...

Page 9: ...Tighten the dome nut on the sealcon to secure the cable Note Clearfield recommends the use of a set of sealcon wrenches P N s 013190 40mm and 013191 42mm to properly tighten the sealcon lock nut and...

Page 10: ...e here https www seeclearfield com assets documents installation manuals clearview blue cassette install manual pdf 4 Remove all Clearview Blue Cassettes from the wall box that need to be spliced This...

Page 11: ...fd net Manual 020012 REV A Aug 2018 After splicing is complete return the cassettes to the wall box and store the buffer tubes securing them with the provided Velcro and bridge lances Note Secure the...

Page 12: ...018 Jumper Installation Access to the jumper side of the wall box is done via the security screw on the outside door Individual jumpers can be inserted through either the upper or lower hole in the en...

Page 13: ...pers leave the radius spools toward the back wall opposite the cable entrance and then transition forward to the adapters This will allow for proper jumper swing if the bulkhead is opened Figure 1 The...

Page 14: ...ead to scratching of the end face Learn the process of cleaning properly Note It is NOT recommended to use isopropyl alcohol to clean the end face Cleaning an SC LC Connector Cleaning the End Face Pla...

Page 15: ...rough an Adapter AND the Adapter Itself Lightly moisten the fiber optic swab 2 5mm 38542F or 1 25mm 38040 by spotting a small amount about 1 of Electro Wash PX or Electro Wash MX pen onto the QbE Hold...

Page 16: ...d of the wipe Figure 1 Figure 1 Figure 2 Figure 3 Hold end face at a 90 degree angle For APC connection adjust by slightly tilting the container or end face Angle is correct when no drag is felt on th...

Page 17: ...lacement at the option of Clearfield Inc shall constitute the exclusive sole remedy for a breach of this limited warranty Clearfield shall not be liable under any circumstances for any special consequ...

Page 18: ...on to efficiently install the equipment supplied Every effort has been made to keep the information contained in this document current and accurate as of the date of publication or revision However no...

Reviews: