Ensuring Client & Host Firmware Compatibility

ClearCube PCoIP clients and host cards must use identical firmware 
versions. If you are upgrading portions of existing ClearCube 
deployments, ensure that all PCoIP devices use the same firmware 
version. Additionally, devices must use firmware version 3.0 or 
higher in a VMware

®

 View environment. See 

PCoIP User’s Guide

 

on the ClearCube Support site for instructions about identifying and 
updating PCoIP device firmware.

Setting up the I9422 Zero Client

Perform the following steps to connect peripherals and a network 
cable to the I9422. 

ENSURE YOU FOLLOW THE MOUNTING & 

COOLING REQUIREMENTS DETAILED BELOW. FAILURE TO 
DO SO CAN DAMAGE THE CLIENT.

1.

Connect a USB keyboard and a pointing device to the USB ports 
on the front or the rear of the I9422.

2.

Connect a CAT5 or CAT6 Ethernet cable to the RJ-45 Ethernet 
jack on the rear of the I9422.

3.

Connect a monitor cable to each DVI-I port on the rear of the 
I9422. If you are using VGA monitors, attach DVI adapters to 
your monitor cables.

4.

Connect the AC power adapter, included with the I9422, to the 
power jack on the rear panel of the I9422.

5.

Connect the AC power adapter to the AC power cable, and then 
plug the cable into a power outlet.

6.

To power on the I9422, briefly press the power button on the 
front of the I9422. The button turns green. 

7.

To power off the I9422, press and hold the power button for three 
seconds. The button turns orange when power is off.

Mandatory Setup & Cooling Requirements

Place the I9422 on a flat surface, as shown in the figures on the 
previous page. Ensure the following in all scenarios:

Ensure at least 4 inches of space around all client edges and at 
least 2 inches of space above the client.

Ambient temperature around a client must not exceed 35° C (95° F).

Do not stack any objects on top of the client.

Do not block the client’s side vents by leaning papers, folders, 
computer speakers, or any other objects against the sides of 
the client.

Adjacent furniture (file drawers, desk supports, chairs) do not 
block or enclose any sides of the client.

Ensure that the client is standing vertically.

Do not place the client in enclosed environments such as on a 
shelf or inside a drawer.

Cables connected to the client are supported.

I9422 Zero Client Buttons and Indicators

The I9422 has the following indicators on the front panel:

Power Button

Green: I9422 is powered on.

Orange: I9422 is powered off.

PCoIP Session Indicator

—Shows when a connection, or 

session, is established between the I9422 and a blade. The 
link indicator displays one of the following:

Green—A session is established between the client and a 
blade.

Off—There is no session between the client and a blade.

Remote PC Power

—When an I9422 is connected to a 

remote PC host, you can press the 

Remote PC

 button on the 

front of the I9422 to put the remote PC in a soft off (S5, hot) 
power state (use a writing pen or a similar object to press the 
remote power button). Press the button again to wake the 
remote PC. Video resumes at the OS login screen. You can 
change the action performed when users press the Remote PC 
power button. See the 

PCoIP User’s Guide

 for more 

information.

Configuration Steps and Additional Information

See 

PCoIP System User’s Guide

 at 

support.clearcube.com 

for 

information about configuring the I9422 Zero Client and for 
instructions about provisioning PCoIP processors on the I9422 
Zero Client.

Email: 

[email protected]

Web site: 

support.clearcube.com

Toll-free: (866) 652-3400

Phone: (512) 652-3400

FCC Compliance & Patent Information

This device complies with part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) This device may not 
cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause 
undesired operation.

The ClearCube C3 architecture and all its components are 
protected by granted and pending U.S. and international patents 
including: US05926172, US05966056, US05994952, 
US06012101, US06020839, US06037884, US06038616, 
US06119146, US06148182, US06167241, and US06886055.

WEEE Disposal Guidelines

In the European Union, this electronic product is under European Directive 
(2002/96/EC) WEEE. When this product reaches the end of its useful life or is 
no longer used, do not discard it with conventional waste. Recycle this 
product at an approved, designated recycling or treatment facility. Check with 
local authorities for proper disposal instructions. For assistance, contact 
ClearCube at 

[email protected]

Reviews: