background image

ClearCube Public Technical Document

Document Code: TB0227TM

ClearCube Technology     

8834 Capital of Texas Hwy N    Austin, Texas 78759

    voice 512 652 3500   www.clearcube.com

4.  

In the 

Action

 pulldown menu, select 

Scan for hardware changes

. The USB device will then be 

detected. 

Note: 

Depending on the security settings on your blade, you may not have access to this feature. If you 

cannot access the Device Manager, contact your system administrator. 

On some versions of the ClearCube-branded PS/2 keyboard, multiple presses of the 

Num Lock

 key 

may cause the 

Caps Lock

 LED to light up, even though 

Caps Lock

 is not actually activated. 

During this error mode, pressing the 

Caps Lock

 key causes the 

Num Lock

 LED also turn on, which then 

enables both the Caps Lock and Num Lock features. 

Workaround: 

Limit your use of the 

Num Lock

 key. If this error is encountered, save your work and discon-

nect your session with the blade. Then power off the I8330, disconnect the keyboard, and reconnect it. 

Turn the I8330 back on and restart your session. 

The 

Num Lock

 LED may not accurately reflect the keyboard number pad functionality. 

This is a function of the I8330 firmware that polls the keyboard controller chip during I8330 startup as well 

as during blade login. 

Workaround: 

Turn the 

Num Lock

 function o

ff

 whenever you connect to a blade. If you notice that the 

Num Lock 

LED on your keyboard inaccurately displays whether the 

Num Lock

 function is set, terminate 

your blade connection and press the 

Num Lock

 key one or more times until the 

Num Lock

 LED goes out. 

Then re-establish the blade connection. Alternatively, ignore the 

Num Lock

 LED. 

An I8330 I/Port flashed to a newer version of firmware can still load older firmware from a blade if it is 

available. 

To ensure successful startup even if no blades can be detected by the I8330 on the network, the
I8330 stores firmware locally. If any blades with the I83xx driver software are detected, the I8330 will
always load its firmware from one of those blades.  The firmware which is loaded will be the most current
of all the versions discovered among the detected blades.  If the firmware contained on the blade is not
the most current version, there may be a mismatch between the firmware version loaded locally and the
firmware version loaded from the blade.

 

Workaround:

 This is by design.  This capability maintains compatibility between the firmware loaded

on the I8330 and the I83xx driver software to which the I8330 will connect.  The system administrator is
responsible for maintaining the current version of the I83xx driver on all blades.  An environment with 
mixed versions of the I83xx driver is not desireable or recommended, since this may lead to 
compatibility issues. 

 

 

 

 

  

 

  

  

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

  

 

 

 

For more information, please contact ClearCube technical support.

[email protected]

Email address for ClearCube Technical Support

support.clearcube.com

ClearCube Support Website

(866) 652-3400

Direct line in the US

+1 (512) 652-3400

Direct line from outside the US