background image

ClearCube Technology     

8834 Capital of Texas Hwy N    Austin, Texas 78759

    voice 512 652 3500   www.clearcube.com

 G0200107 Rev C

7.

Align the 

V5120 card

 and the 

riser card

, as shown in the 

following figure. Gently insert the V5120 gold fingers into the 

riser card’s slot. Ensure that the cards are fully seated.

8.

Insert the cards in the motherboard expansion slot.

a.

Lower the connected cards into the blade, and gently 

place the edge of the 

V5120 card

 between the upper and 

lower rails of the 

support bracket

.

b.

Align the riser card’s 

gold connectors

 with the 16x PCI 

Express® 

expansion slot

 on the mother board. Press 

down firmly to seat the riser card.

9.

Secure the mounting bracket to the top edge of the blade using 

the two SEMS screws included in the kit.

10.

Connect the 

Ethernet cable

 and the four–pin 

signal cable

 to 

the matching connectors on the edge of the V5120 card. 

Connect the other end of the Ethernet cable to the single 

Ethernet connector on the rear of the blade (do not 

connect the cable to the dual Ethernet connector 

adjacent to the power supply).

Connect the other end of the signal cable to the four–pin 

connector on the I/O motherboard on the rear of the blade 

(the letters 

RGH

 are printed above the four–pin connector).

Ensure that you thread the cables under the blade frame’s 

center channel after connecting the cables.

11.

Replace the 

top cover

 and the 

I/O cover

 and screw the covers 

into place (see step 2 and step 3 for screw hole locations).

12.

Remove the backing from the 

V5120 configuration label

 included 

in the kit and place it on the outside of the A1410 blade frame.

Note: 

If a video card configuration label is already on the blade 

in the indicated location (for example, if you are replacing 

or upgrading an existing V5120 or V5140 card), ensure 

that you remove the old label before applying the label in 

the upgrade kit. If you cannot remove the old label, place 

the new label on top of the existing label.

After installing the V5120 card, replace the blade in a cage and 

reconnect power.

Additional Features and Information

See 

A–Series Data Center Products Reference Guide

 on 

support.clearcube.com for more information about blade usage 

and configuration, including topics such as:

Mass storage lockout

Network cabling and site preparation

Chassis and blade installation

Firmware compatibility

Email:

[email protected]

 

Web site:

support.clearcube.com

 

Toll-free:

(866) 652-3400

 

Phone:

(512) 652-3400

Place edge of card 

between rails

Connect

4–Pin Cable 

Here

Connect Ethernet 

Cable Here

Center 

Channel

Place configuration label on outside of

blade frame in this location

Reviews: