P S - 7 0 4 F O U R - C H A N N E L P O W E R S U P P L Y
2 - 5
MULTI-CHANNEL SYSTEM
In a multi-channel system where each channel is run on its own cable and
connected only to single-channel remote stations as in the following diagram,
there are no crosstalk issues because the channels do not share a common ground.
Consult the table “Belden Shielded Cables” in the next section for cable
recommendations.
Figure 2-3: Multi-channel System
In a multi-channel system where multiple channels are run from the PS-704 to
multiple channel stations as in the following diagram, crosstalk can be an issue.
This is because the channels will share a common ground at both ends of the
cable run. If this kind of connection will be used, refer to the section “Crosstalk
Considerations.”
Figure 2-4: Multi-channel to multi-channel
C hannel A
C hannel B
C hannel C
C hannel D
P S - 7 0 4
C hannel A
C hannel B
C hannel C
C hannel D
C hannel A
C hannel B
C hannel C
C hannel D
G nd
G nd
P S - 7 0 4
4 C hannel R emote S tation
to other
R emote
S tations