CleanCraft WSAR 20 Operating Instructions Manual Download Page 4

4

WSAR-Series | Version 1.01

Intended Use

2.2 General safety notes

Stürmer Maschinen GmbH accepts no liability for design 
and technical modifications to the device. 
Claims of any kind for damage due to improper use are ex-
cluded.

3

Intended Use

The device is used exclusively to unwind and rewind the 
water hose. Intended use also includes compliance with 
all information in these instructions. Any use beyond the 
intended use or other use is considered misuse.

3.1 Misuse

3.2 Residual risks

When the water hose reel is used as intended, no resi-
dual risks are identified.

4

Type plate

Fig. 1: Type plate WSAR 20

5

Technical Data

6

Assembly

Step 1: Choose a suitable position on the wall. Mark and 

drill 4 holes to correspond with the holes in the 
wall bracket (Fig. 2).                                              

NOTE:

 The bracket can be installed on other se-

cure structures, but the supplied hardware is for 
wall mounting only.

Fig. 2: Wall mounting

Step 2: Attach the bracket to the wall using the supplied 

screws (Fig. 3A).

Fig. 3: Fastening the bracket and hose reel

Step 3: Align the holes on the hose reel body with the 

vertical holes on the bracket. Insert the swivel 
rod into the holes in the bracket and reel 
housing (Fig. 3B).

ATTENTION!

Do not operate water hose reel in hazardous areas! 

WARNING!
Danger in case of misuse!

Misuse of the device can lead to dangerous situati-
ons. 
-  Only operate the device in the power range speci-

fied in the technical data. 

-  Never bypass or disable the safety devices. 
-  Only operate the unit in a technically perfect condi-

tion.

WSAR 20

WSAR 30

Hose length

20+2 m

30+2 m

Hose diameter

11x15 mm

11x15 mm

Mounting 
height

1,2 - 1,5 m

1,2 - 1,5 m

Weight approx.

7 kg

9 kg

Dimensions 
(LxWxH)

450x200x340 
mm

480x230x380 
mm