background image

Operation

DWS - Series | Version 1.03

13

10 Operation

 

10.1 Fill the pump with water

Step 1: Remove the plug (Pos. 5,Fig. 8) from the filler 

neck and pour in clean water until the pump is 
completely filled with water.

Step 2: Close the filler neck (Pos. 5,Fig. 8)again with the 

screw plug. 

Step 3: Start the pump and make sure that there is no 

water leakage.

DANGER!
Danger to life due to electric shock!

There is danger to life when in contact with live com-
ponents. Switched on electrical components can 
cause uncontrolled movements and lead to serious 
injuries.
-  Disconnect the mains plug before starting any adju-

stments to the water pump.

ATTENTION!

The device must be correctly installed before use. It 
must also be checked that the filter elements are 
correctly installed and powerful.
The device should only be operated, mounted, 
repaired and transported on firm, level ground.
Make sure that the electrical data indicated on the 
engine block match those of the mains to which the 
water pump is to be connected, and that the water 
pump power plug is plugged into the socket.

ATTENTION!

Always disconnect the power plug from the power 
outlet before handling the disconnected water 
pump. 
Always check the supply cable for damage such as 
cracks or signs of aging. If necessary, replace the 
cable before further use.
The replacement of a defective power cord must be 
carried out by the technical service or by qualified 
personnel.
When using an extension cord, make sure that it has 
the same cable dimension as the pump power cable 
and avoid contact of the cables with liquids or co 
ductive surfaces.

WARNING!

Before putting the device into operation, make sure 
that the voltage stated on the rating plate corre-
sponds to the mains voltage.

WARNING!

Before starting the engine, the pump must be com-
pletely filled with water.

ATTENTION!

Make sure that the pump is properly placed and 
ready for use. Check whether all hose connections 
are firmly bolted and undamaged.

ATTENTION!

Before starting the motor, the pump must be com-
pletely filled with water.
Dry running can damage the pump.

NOTE!

When commissioning for the first time, it is essential 
to make sure that the pump housing is completely 
deaerated, even with self-priming pumps - that is, 
filled with water. If this venting is omitted, the pump 
does not suck in the pumped liquid. It is recom- 
mended, but not necessary, in addition to deaerate
the suction line or to fill it with water. 

ATTENTION!

Dry running the pump without pumping water must 
be avoided as lack of water will cause the pump to 
overheat. This can lead to considerable damage to 
the device. In addition, there is very hot water in the 
system, so there is a risk of scalding. With the pump 
hot, unplug the power cord and allow the system to 
cool.

Summary of Contents for 7522100

Page 1: ...W ATER PUMP House water system DWS 1105 Operating Instructions DWS 1105 DWS 1105 P DWS 1105 P ...

Page 2: ...Obligations of the operating company 4 2 3 Requirements to staff 5 2 4 Personal protective equipment 5 2 5 General safety regulations 5 2 6 Safety labels on the water pump 7 3 Intended use 7 3 1 Improper use 7 3 2 Residual risks 7 4 Type plate 8 5 Technical Data 8 6 Transport packaging storage 8 6 1 Delivery 8 6 2 Transport 8 6 3 Packaging 8 6 4 Storage 8 7 Device description 9 7 1 Operation and f...

Page 3: ... ersatzteile stuermer maschinen de We are always interested in valuable experience and knowledge gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limitation of liability All information and notes in these operating instructions were summarised while taking applicable standards and rules the state of the art technology and our lon...

Page 4: ... adapt these if necessary The operating company must unambiguously regu late and determine the responsibilities for installa tion operation troubleshooting maintenance and cleaning The operating company must ensure that all per sons who work with the House water system have read and understood this manual Furthermore she must instruct the staff in regular intervals and in form them about the hazar...

Page 5: ...ipment serves to protect per sons against impairments of safety and health while working The staff member has to wear personal protec tive equipment while performing different tasks on and with the machine which are indicated in the individual paragraphs of these instructions The personal protective equipment is explained in the following paragraph 2 5 General safety regulations Please note the fo...

Page 6: ...not used for a long time drain the piping system to prevent ice from forming in the pump chamber ATTENTION Place the cable so that it can not be sucked into the pump ATTENTION Store the device taking into account its weight viz on a firm level surface and only in a closed room without moisture ATTENTION The pumped liquid can be hot and under high pres sure Before moving or dismantling drain the fl...

Page 7: ...d the ma chine is put to its intended use there are still residual risks which are listed below Risk of injury of upper and lower limbs while equip ment is operating Heat build up on components can cause burns and other injuries Danger of fire and explosions in connection with the absorption of wrong liquids Electrical hazards due to contact with parts and high voltage direct contact or with parts...

Page 8: ...ironment Water pumps must not be stacked on top of each other Also no other items may be parked on it Step1 Turn off the water pump and drain completely Wipe all accessible surfaces and let the water pump dry Step 2 Disconnect the suction and discharge lines from the pump and store in a dry and frost free place at least 5 C Model DWS 1105 DWS 1105 P Length 500 mm 492 mm Width Depth 285 mm 274 mm H...

Page 9: ...atering vegetable green house watering fish farming and poultry raising etc Transfer clean water and other non corrosive liquids with low viscosity do not transport inflammable explo sive gasified liquids and liquids containing solid parti cles or fibers The PH of water must between 6 5 and 8 5 Function This series of pump could be transformed into automatic water pump which is realized through ex...

Page 10: ...ther Pressure or Flow As soon as the water supply is closed and no more water flows the pump switches off The display shows OFF but the pump remains in standby mode As soon as the water supply is opened the pressure sinks and the pump switches itself on again Timer function It is possible to set the switch on and switch off time of the pump By briefly pressing the SET button you switch to the menu...

Page 11: ...ith water ATTENTION The electrical connection must be equipped with a high sensitive fault current circuit breaker RCCB 30 mA ATTENTION Only use an extension cable whose cross section and rubber sheathing correspond at least to the connection cable of the device and are marked with the corresponding abbreviation according to VDE Power plugs and couplings must be splash proof WARNING Danger to life...

Page 12: ...pe The pressure pipe Pos 4 Fig 8 transports the liquid from the pump to the extraction point To avoid flow los ses it is recommended to use a pressure pipe with at least the same diameter as the pressure connection of the pump Install the pressure pipe correctly at the pump and at the respective tapping point ATTENTION The suction pipe must be installed in such a way that it cannot exert any mecha...

Page 13: ...ace the cable before further use The replacement of a defective power cord must be carried out by the technical service or by qualified personnel When using an extension cord make sure that it has the same cable dimension as the pump power cable and avoid contact of the cables with liquids or co ductive surfaces WARNING Before putting the device into operation make sure that the voltage stated on ...

Page 14: ...sed as this may cause damage to the pump due to water overheat ing NOTE The house water system DWS 1105 is equipped with an additional dry running protection and pre filter The dry running protection switches the pump off as soon as no water can be pumped The pre filter filters efficiently sand and similar parti cles from the liquid minimizing wear and extending the service life of the pump ATTENT...

Page 15: ...de vices provided for this purpose 12 Disposal recycling of used device Please take care in your own interest and in the interest of the environment that all component parts of the ma chine are only disposed of in the intended and permit ted way 12 1 Decommissioning Immediately decommission disused machines in order to avoid later misuse and endangering of the environ ment or personal safety Elimi...

Page 16: ...mparatur is too low wa ter froozen 5 The water pipes are defect 1 Fill the pump housing with the water 2 Verify and ensure that the suction pipe and all connections are tight The inlet of the suction pipe including the non re turn valve is immersed in the pumped liquid The non return valve with filter is closes tightly and not blocked There are no siphons bends counter slopes or constrictions alon...

Page 17: ...stem Example The fan wheel for the house water system DWS 1105 must be ordered The fan wheel has the number 44 in the spare parts drawing Type of device House water system DWS 1105 Item number 7522200 Position number 44 The order number is 0 7522200 44 The order number consists of the item number drawing number position number and one digit in front of the item number Place the digit 0 in front of...

Page 18: ...Spare parts drawing DWS 1105 In case of the service the following drawing shall help to identify the necessary spare parts If necessary send a copy of the parts drawing with the marked components to your dealer Fig 9 Spare parts drawing DWS 1105 ...

Page 19: ...Spare parts DWS Series Version 1 03 19 14 3 Spare parts drawing DWS 1105 P Fig 10 Ersatzteilzeichnung DWS 1105 P ...

Page 20: ...20 DWS Series Version 1 03 Electrical wiring diagram 15 Electrical wiring diagram DWS 1105 Fig 11 Electrical wiring diagram DWS 1105 DWS 1105 P Fig 12 Electrical wiring diagram DWS 1105 P ...

Page 21: ...ioned directive as well as the other applied directives below including their applicable modifications at the time of the declaration The following harmonized standards were applied DIN EN 62233 2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure DIN EN 60335 1 2012 Household and similar electrical appliances Safety Part 1...

Page 22: ...www cleancraft de ...

Reviews: